ROCHE MOLECULAR SYSTEMS, INC. - BRANCHBURG COBAS LIAT SARS-COV-2 & INFLUENZA A/B; REAGENTS, 2019-NOVEL CORONAVIRUS NUCLEIC ACID Back to Search Results
Catalog Number 09211101190
Device Problem False Positive Result (1227)
Patient Problems Anxiety (2328); Unspecified Respiratory Problem (4464); No Clinical Signs, Symptoms or Conditions (4582)
Event Date 08/31/2021
Event Type  malfunction  
Manufacturer Narrative
Roche received complaints alleging invalid and/or false positive results with the cobas® sars-cov-2 & influenza a/b test for use on the cobas® liat® system for one or more targets (sars-cov-2, influenza a, influenza b).When reviewing the customer-provided data associated with the reported invalid and false positive results, abnormal pcr curves were observed.Per the on-going investigation, several potential causes for the abnormal pcr growth curves leading to invalids and false positives have been identified.These include tube leaks, abnormal pcr steps, and loose thermal sensor wiring.Overall across the installed base, these issues from product use may occur sporadically.For invalid or false positive influenza results, adverse health consequences are not likely.For invalid sars-cov-2, adverse health consequences are not likely since detectability is high and testing can be performed on alternative platforms.For erroneous positive sars-cov-2 results, there is the possibility of adverse health consequences in high risk individuals.As stated in the instructions for use, clinical correlation with patient history and other diagnostic information is necessary to determine patient infection status.A cobas liat software update to better identify the thermal sensor errors and a new cobas® sars-cov-2 & influenza a/b script to better detect abnormal pcr curves have been launched.The implementation of both the software and the updated script have shown a reduction in the calculated false positive rate.Consignees have been notified.(b)(4).
 
Event Description
In light of the covid-19 pandemic and the subsequent emergency use authorizations (euas) for sars-cov-2 diagnostic tests, the agency has requested heightened reporting beyond the reasonably suggests requirements of 803 to include allegations of false positive or false negative results independent of harm or malfunction or off-label use.Pursuant to the agency¿s instruction, we hereby submit this mdr.The customer alleged discrepant results generated for the cobas® sars-cov-2 & influenza a/b (scfa) assay.A customer from the united states alleged that they received potential false positive.During a review of the problem report it was noticed that on (b)(6), 2021 run #3599 generated an influenza a negative, influenza b positive result for a patient¿s sample analyzed on the cobas® liat® system (s/n (b)(4)).The patient¿s same sample was repeat tested on a different cobas® liat® system (s/n not provided) that generated a sars-cov-2 negative, influenza a negative, influenza b negative result.Patient sample was collected using nasopharyngeal in bd viral transport media.The customer confirmed there was no allegation of harm to the patient.The negative result was reported out to the patient and/or personnel treating the patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
COBAS LIAT SARS-COV-2 & INFLUENZA A/B
Type of Device
REAGENTS, 2019-NOVEL CORONAVIRUS NUCLEIC ACID
Manufacturer (Section D)
ROCHE MOLECULAR SYSTEMS, INC. - BRANCHBURG
1080 us highway 202 south
branchburg NJ 08876
MDR Report Key12565609
MDR Text Key281400291
Report Number2243471-2021-03445
Device Sequence Number1
Product Code QJR
Combination Product (y/n)N
PMA/PMN Number
EUA201779
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional
Remedial Action Notification
Type of Report Initial
Report Date 10/01/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received10/01/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date04/30/2022
Device Catalogue Number09211101190
Device Lot Number10503Z
Date Manufacturer Received09/03/2021
Is This a Reprocessed and Reused Single-Use Device? Yes
Removal/Correction Number2243471-03-17-2021-001-C
Patient Sequence Number1
-
-