SMITH & NEPHEW ORTHOPAEDICS LTD BHR CURVED CUP INTRODUCER; PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/METAL, RESURFACING Back to Search Results
Model Number 90128257
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/22/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Internal reference number: case- (b)(4).
 
Event or Problem Description
It was reported that, during a thr surgery, one bhr curved cup introducer broke.Surgery/treatment was resumed, without any delay, with a back-up device.No health consequences were reported.
 
Additional Manufacturer Narrative
H3, h6: it was reported that during a total hip replacement surgery, the bhr cup introducer broke.No surgical delay or patient harm was reported.A bhr cup introducer (part no.90128257, batch no.S0710151) which was used in treatment was returned for investigation.A review of the historical complaints data for the bhr curved cup introducer was performed using batch numbers to evaluate patterns of repeated failures or defects over the lifetime of the product and using part numbers and the reported failure modes to evaluate patterns of repeated failures or defects in a timeframe of 12 months prior to the date in which the incident was reported.A similar complaint has been identified to involve this batch.Other similar complaints have been identified for the part number and the reported failure mode in this timeframe, and this failure will continue to be monitored.A visual inspection was performed.Marks, scratches, and dents were visible across the whole device, consistent with years of surgical use.Strike cap shows evidence of impact damage.Part of wire grip assembly adjacent to the thumb wheel has snapped so the device no longer functions.This confirms the reported complaint.Laser markings were present, correct, and legible although significantly faded.A functional evaluation was not performed as the instrument was confirmed to be broken/non-functional during visual inspection.This device is a reusable instrument that can be exposed to numerous surgeries, it is unknown how many cycles this instrument has been through in its 14+ years life; damage from repeated use can occur.Due to the age of the instrument reportedly involved in this incident and its reported failure, a dhr review was not performed.However, the released instrument involved would have met manufacturing specifications at the time of production (around 2007).A risk management review was performed.The alleged failure modes and associated risks have been anticipated within the risk file and the anticipated risk level is still adequate.No further actions are required at this time.Based on the information provided and product evaluation of the returned instrument, also taking into account the age of the instrument (13+ years), a probable root cause of the reported failure is the device reaching the end of its useful life.If additional information is received, this case will be reopened.Based on this investigation, the need for corrective and preventative actions is not indicated.The device cannot be repaired and will be retained.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BHR CURVED CUP INTRODUCER
Common Device Name
PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/METAL, RESURFACING
Manufacturer (Section D)
SMITH & NEPHEW ORTHOPAEDICS LTD
aurora house, spa park
leamington spa warwickshire CV31 3HL
UK  CV31 3HL
Manufacturer (Section G)
SMITH & NEPHEW ORTHOPAEDICS LTD
aurora house, spa park
leamington spa warwickshire CV31 3HL
UK   CV31 3HL
Manufacturer Contact
holly topping
7000 west william cannon drive
austin
austin, TX 78735
5123913905
MDR Report Key12582908
Report Number3005975929-2021-00467
Device Sequence Number11064078
Product Code NXT
UDI-Device Identifier03596010533791
UDI-Public03596010533791
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
P040033
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 01/24/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number90128257
Device Catalogue Number90128257
Device Lot NumberS0710151
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/30/2021
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/23/2021
Supplement Date Received by Manufacturer01/24/2022
Initial Report FDA Received Date10/06/2021
Supplement Report FDA Received Date01/24/2022
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Patient SexUnknown
-
-