BOSTON SCIENTIFIC CORPORATION WATCHMAN TRUSEAL ACCESS SYSTEM; SYSTEM, APPENDAGE CLOSURE, LEFT ATRIAL Back to Search Results
Model Number M635TU70010
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Thrombosis/Thrombus (4440)
Date of Event 09/21/2021
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that a thrombosis occurred.A left atrial appendage (laa) closure procedure was being performed.A single curve watchman truseal access system (was) was positioned and a 27mm watchman flx laa closure device & delivery system (wds) were used.An object appearing to be a mobile thrombus was identified on the tip of the was via transesophageal echocardiography (tee) while the device was in the left atrium.This was noticed after transseptal puncture and before the pigtail wire was inserted into the was.The physician aspirated blood through the was, and successfully implanted the closure device.The patient was extubated post index procedure and was doing well post implant.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
WATCHMAN TRUSEAL ACCESS SYSTEM
Common Device Name
SYSTEM, APPENDAGE CLOSURE, LEFT ATRIAL
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key12583696
Report Number2134265-2021-12485
Device Sequence Number3694901
Product Code DQY
UDI-Device Identifier08714729965701
UDI-Public08714729965701
Combination Product (Y/N)N
Initial Reporter StateLA
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 10/06/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date01/06/2024
Device Model NumberM635TU70010
Device Catalogue NumberM635TU70010
Device Lot Number0026587591
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 09/21/2021
Initial Report FDA Received Date10/06/2021
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age67 YR
-
-