• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: SYRINGE 1.0ML 31G 6MM S/C U-100 RELION; PISTON SYRINGE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SYRINGE 1.0ML 31G 6MM S/C U-100 RELION; PISTON SYRINGE Back to Search Results
Model Number 328519
Medical Device Problem Codes Defective Device (2588); Material Deformation (2976)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/09/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Date of event: unknown.Medical device expiration date: na.A device evaluation and/or device history review is anticipated, but is not complete.Upon completion, a supplemental report will be filed.
 
Event or Problem Description
It was reported that syringe 1.0ml 31g 6mm s/c u-100 relion was damaged and had molding defects.This occurred on 7 occasions.The following information was provided by the initial reporter: it was reported customer found 7 barrels that are cracked and have bubble looking bumps in the barrels too.
 
Additional Manufacturer Narrative
The following fields were updated due to additional information: d10: device available for eval yes.D10: returned to manufacturer on: 2021-10-04.H6: investigation summary customer returned (25) loose 31gx6mm, 1ml insulin syringes.The consumer reported found 7 barrels that are cracked and have bubble looking bumps in the barrels too.All 25 returned syringes were examined, and it was observed that 20 out of the 25 syringes exhibited small gouges on the surface of the barrel between the 20- and 30- unit scale markings.All 25 syringes were then tested for flow, and it was observed that all 25 syringes were able to draw and expel properly.No defects inside the barrels were observed.A review of the device history record was completed for batch# 0217457.All inspections were performed per the applicable operations qc specifications.There was one (1) notification noted for damaged barrel.Bd was able to duplicate or confirm the customer¿s indicated failure.H3 other text : see h10.
 
Event or Problem Description
It was reported that syringe 1.0ml 31g 6mm s/c u-100 relion was damaged and had molding defects.This occurred on 7 occasions.The following information was provided by the initial reporter: it was reported customer found 7 barrels that are cracked and have bubble looking bumps in the barrels too.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYRINGE 1.0ML 31G 6MM S/C U-100 RELION
Common Device Name
PISTON SYRINGE
MDR Report Key12594653
Report Number1920898-2021-01049
Device Sequence Number1547817
Product Code FMF
UDI-Device Identifier00681131138345
UDI-Public00681131138345
Combination Product (Y/N)N
Initial Reporter StateNY
Initial Reporter CountryUS
PMA/510(K) Number
K170386
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source consumer,other
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 10/14/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Model Number328519
Device Catalogue Number328519
Device Lot Number0217457
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/04/2021
Initial Date Received by Manufacturer 09/09/2021
Supplement Date Received by Manufacturer10/08/2021
Initial Report FDA Received Date10/07/2021
Supplement Report FDA Received Date11/03/2021
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured08/04/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
-
-