• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION ENDOTAK RELIANCE SG; IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (NON-CRT)

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION ENDOTAK RELIANCE SG; IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (NON-CRT) Back to Search Results
Model Number 0171
Medical Device Problem Code High impedance (1291)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/02/2021
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that the remote home monitor issued an alert for high out of range pacing impedance measurements for the right ventricular (rv) lead.It was noted that the rv lead has exhibited variable impedance measurements between 1600 ohms and 2000 ohms for more than one year.The patient was brought in for a follow-up where provocative maneuvers were performed and no episodes of noise or sudden changes of the pacing impedance measurements were recorded.During the office visit the rv lead impedance measurement was stable around 1800 ohms.The clinic will continue to perform remote interrogations with ambulatory follow ups every six months.The rv lead remains in service and no adverse patient effects were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ENDOTAK RELIANCE SG
Common Device Name
IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (NON-CRT)
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
4100 hamline avenue north
saint paul MN 55112
MDR Report Key12644129
Report Number2124215-2021-29911
Device Sequence Number1204960
Product Code LWS
UDI-Device Identifier00802526373374
UDI-Public00802526373374
Combination Product (Y/N)Y
Initial Reporter CountryIT
PMA/510(K) Number
P910073/S041
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2008
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 10/17/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date11/28/2009
Device Model Number0171
Device Catalogue Number0171
Device Lot Number101802
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 09/02/2021
Initial Report FDA Received Date10/17/2021
Patient Sequence Number1
-
-