MAUDE Adverse Event Report: ANGIODYNAMICS NANOKNIFE SYSTEM; LOW ENERGY DIRECT CURRENT ABLATION SYSTEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ANGIODYNAMICS NANOKNIFE SYSTEM; LOW ENERGY DIRECT CURRENT ABLATION SYSTEM Back to Search Results
Model Number 20400103
Medical Device Problem Codes Material Discolored (1170); Melted (1385)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/23/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The reported device has been returned to the manufacturer and an investigation into the root cause for event is currently in progress.The results of the investigation will be sent via a follow up medwatch.Reference (b)(4).
 
Event or Problem Description
A distributor reported an end user experienced an issue with a nanoknife electrode.After opening the probe packaging, but before starting the procedure, physician noticed that the tip of probe is dark, it looked as if its burnt/charred.The probe had not been placed.It was reported the probe was connected to the unit at the time.The procedure had not been started and the probe had not been activated, however the unit was on at the time.The unit was set to burn at 2700v.It was set aside and the procedure was completed with a new of the same device.The patient did not experience any adverse effects, harm, or require medical intervention because of this incident.The reported device has been returned to the manufacturer and an investigation into the root cause for event is currently in progress.
 
Additional Manufacturer Narrative
Returned for evaluation was one nanoknife probe in its original opened package.As received, the probe shaft was slightly bent when removed from the package.The tip of the nano knife probe appeared burnt/discolored.Per the manufacturing engineer for this product, during the manufacturing process, when the insulation is placed onto the device it is aligned with the trocar tip.There is no heat used in the process where it would cause damage after the insulation is installed.Any defects like this would be captured during this assembly process.Likely something outside of the process before packaged or after received by customer caused the damage.The customer's reported complaint description was confirmed as the insulation sleeve at the tip of the probe was observed to be melted/burnt.The root cause is likely from the tip of the insulation being too close to high heat.Angiodynamics is unable to definitively determine when or where the heat was applied to the device to cause the melting of the insulation; either during manufacturing process or end user facility.The root cause of this product damaged event is unknown, however, this is the only reported complaint of this failure mode for the nanoknife a review of the device history records was performed for the indicated lots for any deviations related to the reported failure mode of the complaint.The review confirms that the lots met all material, assembly and performance specifications; i.E.No ncr associated with reported failure mode.Labeling review: the instructions for use which is supplied to the end user, states: "warnings: do not use a device with damaged insulation.Do not attach anything to the device unless it is supplied by angiodynamics and indicated for use with this device.Attachments may damage the insulation and contribute to patient injury.Adverse effects that may be associated with the use of the nanoknife system include, but are not limited to: arrhythmia, atrial, fibrillation or flutter, bigeminy, bradycardia, heart block or atrioventricular block, paroxysmal supraventricular tachycardia, tachycardia, reflex tachycardia, ventricular tachycardia, ventricular fibrillation, fistula formation, damage to critical anatomical structure (nerve, vessel, duct), hematoma, hemorrhage, hemothorax, infection, muscle contraction pneumothorax, reflex.A review of the angiodynamics complaint system noted no adverse trends for this complaint type and product family.This type of complaint will continue to be monitored for trends.Reference (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NANOKNIFE SYSTEM
Common Device Name
LOW ENERGY DIRECT CURRENT ABLATION SYSTEM
Manufacturer (Section D)
ANGIODYNAMICS
10 glens falls technical park
glens falls, ny 12801 NY 12801
Manufacturer (Section G)
ANGIODYNAMICS
10 glens falls technical park
glens falls, ny 12801 NY 12801
Manufacturer Contact
alexandra invencio
26 forest street
marlborough, MA 01752
5086587805
MDR Report Key12658577
Report Number1319211-2021-00072
Device Sequence Number4851978
Product Code OAB
UDI-Device IdentifierH787204001030
UDI-PublicH787204001030
Combination Product (Y/N)N
Initial Reporter CountrySN
PMA/510(K) Number
K080287
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Distributor
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 12/13/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date09/30/2023
Device Model Number20400103
Device Catalogue Number20400103
Device Lot Number5636580
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/11/2021
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/26/2021
Supplement Date Received by Manufacturer12/10/2021
Initial Report FDA Received Date10/19/2021
Supplement Report FDA Received Date12/13/2021
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured10/06/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-