Model Number 0450000000
Device Problems Adverse Event Without Identified Device or Use Problem (2993); Pumping Problem (3016)
Patient Problems Extravasation (1842); No Clinical Signs, Symptoms or Conditions (4582)
Event Date 09/28/2021
Event Type  malfunction  
Manufacturer Narrative
Additional information will be provided once the investigation has been completed.The device manufacturer date is not known at this time.However, should it become available it will be provided in future reports.
 
Event Description
It was reported that there was extravasation.
 
Manufacturer Narrative
The product was not returned for investigation and the reported failure mode was not confirmed.Alleged failure: pump does not stop.Probable root cause: pressure sensor malfunction/out of calibration; inflow cassette/ tubing pressure sensor membrane failure; mis-inserted cassette/ tubing; motor encoder malfunction/failure (inflow and/or outflow); roller wheel assembly (inflow and/or outflow) malfunction/failure; roller wheel failure due to peristaltic tubing debris build-up; main board (all) /imx failure (cf); software malfunction; use error; system design; unwanted movement of internal components/wiring; pressure sensor is operated above linear pressure reading range (>450 mmhg for cf) (design); pump operated at least-favorable environmental conditions for extended period of time; run screen does not adequately indicate overpressure situation; miniwashmalfunction (cf); command not registered from hand control (all), footswitch (cf), sidne (fc, ap) or hermes (ap-hermes ready); excessive use of wash or turbo; slow reaction time to a quickly closed off shaver outflow at high flow rates; power failure of pump; pressure sensor stuck behind the sensor bracket; electromagnetic interference (emi) from rf communication, hf surgical instruments, esd, or power surge; insufficient cybersecurity (cf).Serial number is unknown; therefore, manufacture date can not be confirmed.The failure mode will be monitored for future reoccurrence.H3 other text : 81.
 
Event Description
It was reported that there was extravasation.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PKG, CROSSFLOW CONSOLE
Type of Device
ARTHROSCOPE
Manufacturer (Section D)
STRYKER ENDOSCOPY-SAN JOSE
5900 optical court
san jose CA 95138
Manufacturer (Section G)
STRYKER ENDOSCOPY-SAN JOSE
5900 optical court
san jose CA 95138
Manufacturer Contact
andrea zenere
5900 optical court
san jose, CA 95138
4087542000
MDR Report Key12701354
MDR Text Key278524789
Report Number0002936485-2021-00568
Device Sequence Number1
Product Code HRX
UDI-Device Identifier07613327058048
UDI-Public07613327058048
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K123441
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Company Representative
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 12/22/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received10/26/2021
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number0450000000
Device Catalogue Number0450000000
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Date Manufacturer Received09/28/2021
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
Patient Outcome(s) Other;
-
-