• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: C.R. BARD, INC. (COVINGTON) -1018233 ALIGN TO URETHRAL SUPPORT SYSTEM - HALO; ALIGN® TO URETHRAL SUPPORT SYSTEM - HALO

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

C.R. BARD, INC. (COVINGTON) -1018233 ALIGN TO URETHRAL SUPPORT SYSTEM - HALO; ALIGN® TO URETHRAL SUPPORT SYSTEM - HALO Back to Search Results
Model Number BRD500HL
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Unspecified Infection (1930)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
The reported event could not be confirmed.No sample was returned for evaluation.Based on the investigation findings, current manufacturing controls are considered adequate as to detect and segregate any non-conforming unit.Event described could not be confirmed as a manufacturing related issue.The alleged event is most likely associated with possible procedural/surgical complications.The ifu currently addresses potential risks associated with surgically implantable materials which states the following: precautions: the usual precautions associated with urological procedures should be followed: based on physician experience and training, a thorough assessment of each patient should be made to determine their suitability for the implant procedure.Additional consideration should be given to use of the implant in patients with a compromised immune system, any condition that would compromise healing, or any patient with a history of prior abdominal or pelvic surgeries.Consideration should also be given to the ability of the patient to tolerate the surgical procedure.Accepted surgical practice and precautions must be followed for the management of contaminated or infected wound sites, when the align® to urethral support system is used.Postoperative bleeding may occur in some patients and must be controlled prior to patient release.The implant procedure requires diligent attention to anatomical structures and care to avoid puncture of large vessels, nerves, bladder, bowel, urethra and any viscera, during introducer passage.Due to anatomical distortion that can be caused by pelvic organ prolapse, if the patient requires cystocele repair, it should be performed prior to the implantation of the sub-urethral sling.Proper placement of the sling implant at the mid-urethra requires that it lie flat with minimal or no tension under the urethra.The align® to urethral support system is intended as a single-use device.Do not re-sterilize any portion of the align® to urethral support system.Reuse and/or repackaging may create a risk of patient or user infection, compromise the structural integrity and/or essential material and design characteristics of the device, which may lead to device failure, and/or lead to injury, illness or death of the patient.Patients should be advised that pregnancy following a sling implant procedure may negatively affect the success of the previous implant procedure and incontinence may recur.The safety and effectiveness of the align® to urethral support system implant procedure has not been established for the treatment of stress urinary incontinence in males and children under the age of 18.Cystoscopy can be considered at the physician¿s discretion.Check the integrity of the packaging before use.Do not use the align® to urethral support system if the packaging is opened or damaged.As for any implantable material, it is recommended to open the package at the time of implantation.Post-operatively the patient should be advised to refrain from heavy lifting, exercise (e.G.Cycling, jogging) and/or intercourse until the physician determines it is suitable for the patient to return to normal activities.Adverse events: complications associated with the proper implantation of the align® to urethral support system may include, but are not limited to: postoperative hematoma, seroma, abscess or fistula formation, or scarring which may occur following the implant procedure.Urinary retention, bladder outlet obstruction and other voiding dysfunctions.These conditions may be associated with over-correction/too much tension placed on the implant.Perforations or lacerations of vessels, nerves, bladder, bowel, urethra, or any viscera, which may occur during the implantation procedure.Irritation at the operative wound site which may elicit a foreign body response that leads to wound dehiscence, inflammation and/or infection.Extrusion through vaginal epithelium or erosion into surrounding viscera and/or mucosa.Inflammation, sensitization, pain, dyspareunia, scarification, contraction, device migration and failure of the procedure resulting in recurrence of incontinence.(b)(4).
 
Event or Problem Description
The patient's attorney alleged a deficiency against the device.Additional information has been requested, but not yet received.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ALIGN TO URETHRAL SUPPORT SYSTEM - HALO
Common Device Name
ALIGN® TO URETHRAL SUPPORT SYSTEM - HALO
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
MDR Report Key12710782
Report Number1018233-2021-80083
Device Sequence Number1454476
Product Code OTN
UDI-Device Identifier00801741016226
UDI-Public(01)00801741016226
Combination Product (Y/N)N
PMA/510(K) Number
K093747
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2015
Reporter Type Manufacturer
Report Source other
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date (Section B) 10/28/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date11/30/2016
Device Model NumberBRD500HL
Device Catalogue NumberBRD500HL
Device Lot NumberHUYJ1511
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Device Age4 MO
Event Location Hospital
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 10/15/2021
Initial Report FDA Received Date10/28/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age38 YR
-
-