Model Number 4.13.912
Medical Device Problem Code Loss of Osseointegration (2408)
Health Effect - Clinical Code Inadequate Osseointegration (2646)
Date of Event 07/05/2021
Type of Reportable Event Serious Injury
Event or Problem Description
Loss of osseointegration, implant achieved osseointegration, primary stability was achieved, implant was completely covered with bone, no thread tap used, periodontal disease, pain, mobility (2021_1944, 2021_1945 and 2021_1946 are same patient).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ELEMENT IMPL., PF 5.0, E Ø 5.0, L 11.0
Common Device Name
DENTAL IMPLANT
Manufacturer (Section D)
THOMMEN MEDICAL AG
neckarsulmstrasse 28
grenchen 2540
CH  2540
Manufacturer (Section G)
THOMMEN MEDICAL AG
neckarsulmstrasse 28
grenchen 2540
CH   2540
Manufacturer Contact
astrid weber
neckarsulmstrasse 28
grenchen 2540
CH   2540
MDR Report Key12766509
Report Number3003184527-2021-01599
Device Sequence Number19915066
Product Code DZE
UDI-Device Identifier07640156471472
UDI-Public07640156471472
Combination Product (Y/N)N
Initial Reporter CountryDE
PMA/510(K) Number
K072649
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2010
Device Explanted Year2021
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Dentist
Type of Report Initial
Report Date (Section B) 11/05/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date01/21/2015
Device Model Number4.13.912
Device Lot Number6705
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/05/2021
Initial Report FDA Received Date11/08/2021
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured01/21/2010
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient Age73 YR
Patient SexMale
Patient EthnicityNon Hispanic
Patient RaceWhite
-
-