BOSTON SCIENTIFIC CORPORATION DYNAMIC XT; CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING Back to Search Results
Model Number 86706
Medical Device Problem Code Detachment of Device or Device Component (2907)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/02/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The device was returned to boston scientific for analysis.Visual inspection found the device has a kink on the shaft, also the tip is detached from the shaft with no adhesive residues observed.Functional test shows that the plunger functioned properly.No abnormal resistance was felt when actuating the steering mechanism.The test curve passes; the curve is less than the specification of 4.5cm.The curve also passes the out-of-plane test.The device passed the dimensional test.Microscope inspection found the tip is out of the shaft and no adhesive residues were observed.X-ray inspection showed tip detachment confirmed.The manufacturing batch record review confirmed that the device met all material, assembly and performance specifications.
 
Event or Problem Description
Reportable based on device analysis completed on 21oct2021.It was reported that before a procedure to treat atrial fibrillation a dynamic xt catheter was selected for use.The shaft was bent while removing the packaging, the package was in good conditions.The issue was solved by exchanging the catheter and the procedure was successfully completed with no patient complications.However, device analysis revealed the tip was detached from the shaft.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DYNAMIC XT
Common Device Name
CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
302 parkway, global park
la aurora - heredia
CS  
Manufacturer Contact
timothy degroot
4100 hamline avenue north
dc a330
saint paul, MN 55112
6515826168
MDR Report Key12790392
Report Number2134265-2021-14189
Device Sequence Number20040953
Product Code DRF
UDI-Device Identifier08714729877615
UDI-Public08714729877615
Combination Product (Y/N)N
Initial Reporter CountryTW
PMA/510(K) Number
K921872
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 11/10/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date04/01/2023
Device Model Number86706
Device Catalogue Number86706
Device Lot Number0025430677
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/21/2021
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 10/21/2021
Initial Report FDA Received Date11/10/2021
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured04/01/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1