• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: DEPUY INTERNATIONAL LTD - 8010379 DXTEND MOD EPI 1 ECC LEFT HA; DELTA XTEND IMPLANTS : SHOULDER HUMERAL STEM ACCESSORY

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

DEPUY INTERNATIONAL LTD - 8010379 DXTEND MOD EPI 1 ECC LEFT HA; DELTA XTEND IMPLANTS : SHOULDER HUMERAL STEM ACCESSORY Back to Search Results
Model Number 130720102
Medical Device Problem Code Difficult to Insert (1316)
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 01/01/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Product complaint # (b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
During the procedure, the surgeon noticed that mating the epiphysis to the stem seemed more difficult than usual and tried two different combinations.He successfully impacted one epiphysis to a stem and engaged the attaching screw successfully implanting both pieces and completing the surgery.No adverse events occurred beside a 3-5 minute delay when retrieving the other implants and the surgeon manually solving the issue.Doe: (b)(6) 2021.
 
Additional Manufacturer Narrative
Product complaint # (b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes joint reconstruction, or its employees that the report constitutes an admission that the product, depuy synthes joint reconstruction, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
 
Additional Manufacturer Narrative
Product complaint # (b)(4).Investigation summary: examination of the returned device confirmed the reported allegation.Cause traced to the mating device.There was no quality issue identified with the delta xtend epiphysis.Depuy synthes considers the investigation closed at this time.Should additional information be received, the information will be reviewed and the investigation may be re-opened as necessary.Device history lot: oms/dhr review: product code 130720102, work order (b)(4) was manufactured on 06-aug-2021.All raw materials met specification.11 parts were manufactured to specification.One (1) part from this lot was scrapped: - scrap code a1112: epi ctq 21 - notch symmetry at issue material process step.This concerns epi ctq 21 ¿ notch symmetry.There is no correlation between this scrap reason and the failure mode of the complaint.There were no non-conformances associated with this lot.There was no material reprocessing reports (mrr) associated with this lot.Device history review : a review was completed of the dxtend mod epi 1 ecc left ha (product code: 130720102 lot number: 9858122) device history record (dhr) and no nonconformances were found.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DXTEND MOD EPI 1 ECC LEFT HA
Common Device Name
DELTA XTEND IMPLANTS : SHOULDER HUMERAL STEM ACCESSORY
Manufacturer (Section D)
DEPUY INTERNATIONAL LTD - 8010379
st. anthony's road
leeds LS11 8DT
UK  LS11 8DT
Manufacturer (Section G)
DEPUY INT'L LTD. 8010379
st. anthony's rd
leeds LS11 8 DT
UK   LS11 8 DT
Manufacturer Contact
kara ditty-bovard
700 orthopaedic dr.
warsaw, IN 46581-0988
6107428552
MDR Report Key12850054
Report Number1818910-2021-25809
Device Sequence Number5094737
Product Code HSD
UDI-Device Identifier10603295027294
UDI-Public10603295027294
Combination Product (Y/N)N
Initial Reporter StateLA
Initial Reporter CountryUS
PMA/510(K) Number
K192448
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 11/03/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date07/31/2026
Device Model Number130720102
Device Catalogue Number130720102
Device Lot Number9858122
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/26/2021
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/03/2021
Supplement Date Received by Manufacturer11/26/2021
05/11/2022
Initial Report FDA Received Date11/21/2021
Supplement Report FDA Received Date12/16/2021
05/11/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured08/06/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
DXTEND METAGLENE.; DXTEND MOD CENT EPI 1 HA.; DXTEND MOD EPI 1 ECC LEFT HA.; DXTEND SCREW LOCK D4.5X24MM.; DXTEND SCREW NO LOCK D4.5X18MM.; DXTEND SCREW NO LOCK D4.5X18MM.; DXTEND SCREW NO LOCK D4.5X18MM.; DXTEND STAND PE CUP D38 +9MM.; GLOBAL UNITE STD STEM SZ 8.; GLOBAL UNITE STD STEM SZ 8.; XTND GLENO D38MM +2MM.
Patient Age75 YR
Patient SexFemale
-
-