CARDIOVASCULAR SYSTEMS, INC. DIAMONDBACK 360 PERIPHERAL ORBITAL ATHERECTOMY SYSTEM; PERIPHERAL ATHERECTOMY DEVICE Back to Search Results
Model Number PRD-SC30-200
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Vascular Dissection (3160)
Date of Event 10/27/2021
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
The oad was received at csi for analysis.A guide wire could not pass through the oad and detailed analysis revealed that the driveshaft was overloaded at the lap weld.Driveshaft overloading is an indication that the spinning driveshaft met sudden resistance bringing it to a stall condition, however this could not be confirmed and the root cause of the driveshaft damage remains undetermined.The device data log identified stall events which confirmed the stopped spinning event.At the conclusion of the device analysis investigation, the report that a dissection occurred could not be confirmed through analysis, and the stopped spinning event was confirmed through the device data log.In the opinion of the physician, the cause of the dissection was unknown.The device history record for this oad lot number has been reviewed.No issues or discrepancies were noted during this review that would have contributed to the reported event.The device met material, assembly, and quality control requirements.(b)(4).
 
Event or Problem Description
The stealth peripheral orbital atherectomy device (oad) was operated on low and medium speed for two treatment passes each.The oad stopped spinning abruptly when operated on high speed.The oad was removed, and a type d dissection was observed.Balloon angioplasty was performed to resolve the dissection.A second oad was used to complete treatment to the distal area of the lesion.The patient was discharged without additional complications.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DIAMONDBACK 360 PERIPHERAL ORBITAL ATHERECTOMY SYSTEM
Common Device Name
PERIPHERAL ATHERECTOMY DEVICE
Manufacturer (Section D)
CARDIOVASCULAR SYSTEMS, INC.
1225 old highway 8 nw
saint paul MN 55112
Manufacturer (Section G)
CARDIOVASCULAR SYSTEMS, INC.
1225 old highway 8 nw
saint paul MN 55112
Manufacturer Contact
brittany leider
1225 old highway 8 nw
saint paul, MN 55112
6512591600
MDR Report Key12852003
Report Number3004742232-2021-00383
Device Sequence Number20107410
Product Code MCW
UDI-Device Identifier10850000491295
UDI-Public(01)10850000491295(17)230331(10)372082-1
Combination Product (Y/N)N
Initial Reporter StateAR
Initial Reporter CountryUS
PMA/510(K) Number
K190634
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 11/22/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date03/31/2023
Device Model NumberPRD-SC30-200
Device Catalogue Number7-10059-04
Device Lot Number372082-1
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/04/2021
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/27/2021
Initial Report FDA Received Date11/22/2021
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured07/02/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age69 YR
Patient SexMale
Patient Weight100 KG
Patient EthnicityNon Hispanic
Patient RaceWhite
-
-