| Catalog Number |
5990011 |
| Medical Device Problem Codes |
Defective Device (2588); Patient-Device Incompatibility (2682); Patient Device Interaction Problem (4001)
|
| Health Effect - Clinical Codes |
Hernia (2240); Insufficient Information (4580)
|
| Date of Event |
04/28/2021
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
No conclusions can be made.The patient's attorney alleges adverse patient outcome associated with the hernia mesh used to treat the patient.The patient's attorney alleges that the patient had subsequent surgical intervention; however, no details have been provided.No lot number has been provided; therefore, a review of the manufacturing records is not possible.Should additional information be provided, a supplemental emdr will be submitted.
|
| |
|
Event or Problem Description
|
|
Attorney alleges that the patient underwent surgery for implant of an unspecified bard/davol ventralight st on (b)(6) 2020.As reported, the patient is making a claim for an adverse patient outcome against the ventralight st.It is alleged that the patient had subsequent surgical intervention due to the hernia mesh device.Attorney alleges that the patient experienced emotional distress and the device was defective.
|
| |
|
Event or Problem Description
|
|
Attorney alleges that the patient underwent surgery for implant of an unspecified bard/davol ventralight st on (b)(6) 2020.As reported, the patient is making a claim for an adverse patient outcome against the ventralight st.It is alleged that the patient had subsequent surgical intervention due to the hernia mesh device.Attorney alleges that the patient experienced emotional distress and the device was defective.Addendum per additional information provided: (b)(6) 2020- patient was diagnosed with epigastric hernia and bilateral inguinal hernias thereby underwent robotic assisted repair with the implant of ventralight st mesh using echo ps 2 (device 1) for epigastric hernia and implant of two 3dmax light mesh (device 2 and 3) for bilateral inguinal hernias.Per op notes, "epigastric hernia was noted, a ventralight st mesh using echo ps 2 (device 1) was placed into the abdominal cavity using sutures.Two 3dmax light mesh (device 2 and 3) were placed on both the right and left inguinal hernias." (b)(6) 2021 - patient was diagnosed with recurrent epigastric hernia thereby underwent robotic assisted repair with the implant of ventralight st mesh using echo ps 2 (device 4).Per op notes, "the previously placed mesh (device 1) was separated from the abdominal wall.A ventralight st mesh using echo ps 2 (device 4) was placed into the abdominal cavity using sutures." (note: the previously placed 3dmax light mesh (device 2 and 3) were not seen during this procedure).
|
| |
|
Additional Manufacturer Narrative
|
|
No conclusions can be made.The patient's attorney alleges adverse patient outcome associated with the hernia mesh used to treat the patient.The patient's attorney alleges that the patient had subsequent surgical intervention; however, no details have been provided.No lot number has been provided; therefore, a review of the manufacturing records is not possible.Addendum: h11: this supplemental emdr is submitted to document additional information provided and to correct the brand name.Root cause is inconclusive; no conclusion can be made as to the extent to which the implant may have caused or contributed to the patient's postoperative course.Note, the manufacturing date (15-feb-2019) is considered to be a best estimate.Note: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|