MAUDE Adverse Event Report: ABBOTT IRELAND SARS-COV-2 IGG REAGENT KIT; REAGENT, CORONAVIRUS SEROLOGICAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ABBOTT IRELAND SARS-COV-2 IGG REAGENT KIT; REAGENT, CORONAVIRUS SEROLOGICAL Back to Search Results
Model Number 06R9020
Medical Device Problem Code False Positive Result (1227)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/01/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
An evaluation is in process.A follow-up report will be submitted when the evaluation is complete.
 
Event or Problem Description
A literature article by samantha ngamsuntikul, jose quesada, and rachel beddard, ¿sars-cov2 antibody testing: a comparison of two assay platforms to designate convalescent plasma as high titer¿, transfusion 61.Suppl 3: 154a-155a.Blackwell publishing inc.(sep 2021), documented a false positive alinity i sars-cov-2 igg result for one donor who was resulted as negative on the vitros assay.The aim of the study was to determine which platform (alinity i vs vitros) provided the most units that could be designated as high titer for patient use.Per the article: covid-19 convalescent plasma was deployed as an early therapeutic with our center starting collections in april of 2020.The fda subsequently required the labeling of these units as high or low titer per minimum antibody cutoff levels for each authorized assay.Because of the center's affiliation with a sister organization that performs blood and plasma center testing, we had access to two different platforms for quantitative covid-19 antibody testing.Between october 2020 and january 2021, 233 paired convalescent plasma donor samples were tested for antibody levels using the anti-sars-cov-2 igg assay on the vitros (ortho clinical diagnostics) and the sars-cov-2 igg assay on the alinity i (abbott diagnostics).The study data was grouped into nonreactive, low tier, and high titer per fda cutoffs.There were three donors who tested as nonreactive on the alinity i but resulted as high titer on the vitros.There was one donor who tested as a low titer on the alinity i but resulted as negative on the vitros.Out of the 233 samples, 7 were nonreactive, 118 were low titer, and 108 were high titer on the alinity i.Out of the 233 samples, 3 were reactive, 78 were low titer, and 152 were high titer.No impact to patient management was reported.No impact to patient management was reported.
 
Additional Manufacturer Narrative
The complaint investigation for false positive results for one donor with the sars-cov-2 igg assay on the alinity i processing module included a review of data and information of the article ¿sars-cov2 antibody testing: a comparison of two assay platforms to designate convalescent plasma as high titer¿, ticket trending review, labeling review, device history record, and in-house testing.Trending review did not identify any trends for the issue for the product.Device history record review did not identify any related non-conformances or deviations with list number 06r90 and the complaint issue.As the likely cause lot number was unknown, testing was performed on a representative reagent lot.Specificity and sensitivity testing was performed using an in-house retain kit of lot 24570fn00.All specifications were met indicating the assay is performing acceptably in the field.Labeling was reviewed and found to adequately address the issue under review.Based on the investigation, no systemic issue or deficiency of the sars-cov-2 igg assay, lot number unknown was identified.Section g1 has been updated to current contact information.
 
Event or Problem Description
A literature article by samantha ngamsuntikul, jose quesada, and rachel beddard, ¿sars-cov2 antibody testing: a comparison of two assay platforms to designate convalescent plasma as high titer¿, transfusion 61.Suppl 3: 154a-155a.Blackwell publishing inc.(sep 2021), documented a false positive alinity i sars-cov-2 igg result for one donor who was resulted as negative on the vitros assay.The aim of the study was to determine which platform (alinity i vs vitros) provided the most units that could be designated as high titer for patient use.Per the article: covid-19 convalescent plasma was deployed as an early therapeutic with our center starting collections in april of 2020.The fda subsequently required the labeling of these units as high or low titer per minimum antibody cutoff levels for each authorized assay.Because of the center's affiliation with a sister organization that performs blood and plasma center testing, we had access to two different platforms for quantitative covid-19 antibody testing.Between october 2020 and january 2021, 233 paired convalescent plasma donor samples were tested for antibody levels using the anti-sars-cov-2 igg assay on the vitros (ortho clinical diagnostics) and the sars-cov-2 igg assay on the alinity i (abbott diagnostics).The study data was grouped into nonreactive, low tier, and high titer per fda cutoffs.There were three donors who tested as nonreactive on the alinity i but resulted as high titer on the vitros.There was one donor who tested as a low titer on the alinity i but resulted as negative on the vitros.Out of the 233 samples, 7 were nonreactive, 118 were low titer, and 108 were high titer on the alinity i.Out of the 233 samples, 3 were reactive, 78 were low titer, and 152 were high titer.No impact to patient management was reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SARS-COV-2 IGG REAGENT KIT
Common Device Name
REAGENT, CORONAVIRUS SEROLOGICAL
Manufacturer (Section D)
ABBOTT IRELAND
finisklin business park
sligo F91VY 44
EI  F91VY44
Manufacturer (Section G)
ABBOTT IRELAND
finisklin business park
sligo F91VY 44
EI   F91VY44
Manufacturer Contact
siobhan wright
lisnamuck
post market surveillance
longford, IL N39 E-932
2246682940
MDR Report Key12863336
Report Number3008344661-2021-00207
Device Sequence Number19176800
Product Code QKO
UDI-Device Identifier00380740192129
UDI-Public00380740192129
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Literature
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 01/20/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number06R9020
Device Catalogue Number06R90-20
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 11/01/2021
Supplement Date Received by Manufacturer01/18/2022
Initial Report FDA Received Date11/23/2021
Supplement Report FDA Received Date01/20/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
ALNTY I PROCESSING MODU, 03R65-01, 205UNKNOWN01.; ALNTY I PROCESSING MODU, 03R65-01, 205UNKNOWN01.
Patient SexUnknown
-
-