C.R. BARD, INC. (BASD) -3006260740 WINGED INFUSION SET 20G X 0.75IN; NEEDLE, HYPODERMIC, SINGLE LUMEN Back to Search Results
Model Number N/A
Medical Device Problem Code Tear, Rip or Hole in Device Packaging (2385)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/30/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The manufacturer has received the sample and will evaluate.Results are expected soon.A lot history review (lhr) of refu0856 showed one other similar product complaint(s) from this lot number.The complaints for this lot number (refu0856) have been reported from the same facility in (b)(6).
 
Event or Problem Description
It was reported, "the needles came damaged, some of them were dusty and the two of them came in damaged box, so they are not sterile anymore." this report addresses the first of the two needles that were damaged.
 
Event or Problem Description
It was reported, "the needles came damaged, some of them were dusty and the two of them came in damaged box, so they are not sterile anymore." this report addresses the first of the two needles that were damaged.
 
Additional Manufacturer Narrative
H11: section a through f the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The following were reviewed as part of this investigation: patient severity, complaint and lot history review, applicable previous investigation(s), sample (if available), labeling, applicable manufacture records, and applicable fmea documents.Based on a review of this information, the following was concluded: the complaint of damaged packaging is confirmed; however, the exact cause is unknown.Two photographs of two winged infusion set kits were returned for evaluation.An initial visual observation of the photographs showed small tears in the tyvek of both kits.The majority of the packaging of the kits was observed to be wrinkled.A grey-colored residue was observed on the front of the kits.The clear plastic of the packaging was also observed to be damaged, and the shape of this damage on at least one of the kits in the returned photographs was found to be very similar the shape of the pinch clamp of the product within the kit.It could not be determined from the returned photographs when or where the samples were damaged.Possible contributing factors include damage during shipping, storage, or handling.H3 other text : evaluation findings are in section h.11.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
WINGED INFUSION SET 20G X 0.75IN
Common Device Name
NEEDLE, HYPODERMIC, SINGLE LUMEN
Manufacturer (Section D)
C.R. BARD, INC. (BASD) -3006260740
605 north 5600 west
salt lake city 84116
Manufacturer (Section G)
BARD REYNOSA S.A. DE C.V. -9617592
blvd. montebello #1
parque industrial colonial
reynosa, tamaulipas 88780
MX   88780
Manufacturer Contact
kelsey erickson
605 north 5600 west
salt lake city 84116
8015950700
MDR Report Key12870251
Report Number3006260740-2021-05022
Device Sequence Number12268396
Product Code FMI
UDI-Device Identifier00801741065804
UDI-Public(01)00801741065804
Combination Product (Y/N)N
Initial Reporter CountryPL
PMA/510(K) Number
K863606
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 12/29/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberN/A
Device Catalogue Number0604190
Device Lot NumberREFU0856
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/23/2021
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 09/30/2021
Supplement Date Received by Manufacturer12/29/2021
Initial Report FDA Received Date11/24/2021
Supplement Report FDA Received Date12/30/2021
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured07/01/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-