• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: DEPUY MITEK LLC US LUPINELOOPPLUS ANCHOR W/OC DS; SOFT-TISSUE ANCHOR, BIOABSORBABLE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

DEPUY MITEK LLC US LUPINELOOPPLUS ANCHOR W/OC DS; SOFT-TISSUE ANCHOR, BIOABSORBABLE Back to Search Results
Model Number 210709
Medical Device Problem Codes Break (1069); Material Deformation (2976)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 10/01/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Udi: (b)(4).To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.
 
Event or Problem Description
It was reported by the customer in (b)(6) that during an unknown surgery on (b)(6) 2021, it was observed that the lupineloopplus anchor w/oc ds device was deformed and broken.Another like device was used to complete the procedure.There were no adverse patient consequences nor surgical delay reported.No additional information was provided.
 
Additional Manufacturer Narrative
This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by mitek or its employees that the report constitutes an admission that the device, mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.Investigation summary: the complaint device is not being returned, therefore unavailable for a physical evaluation, however a photo was provided.Upon visual inspection of the photo, it was found the two devices are not inside their original packaging, the anchors are broken, the sutures are not shown.A manufacturing investigation will be started in order to provide the root cause.A manufacturing record evaluation was performed for the finished device 7l02705 number, and no non-conformances were identified.As part of depuy synthes mitek quality process all devices are manufactured, inspected, and released to approved specifications.According with the visual inspection, this complaint can be confirmed.The investigation was performed by the manufacturing department with the following results: a complaint research, with the same defect did not show another case with this issue from 2019 to now with the items reference 210709.No nr was found during the research.Based on the above, it is confirmed that the manufacturing process has been performed according to the validated processes.The bounding is limited on this part as the complaint analysis shows that there is no other occurrence of such defect for this batch, the batch before and the batch after.A manufacturing investigation activity has been performed to determine if there were any internal processing issues which would have contributed to the nature of the product complaint.According with the investigation results, we can conclude this issue to be an isolated case.At this point in time, no corrective action is required, and no further action is warranted.However, depuy synthes mitek will continue to monitor additional complaint information for potential safety signals through complaint trending as part of post market surveillance.Device history lot: there was no non conformance regarding this lot.
 
Additional Manufacturer Narrative
This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by mitek or its employees that the report constitutes an admission that the device, mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.D9, h3, h6: the actual device has been returned and is currently pending evaluation.Once reliability engineering evaluates the device, a supplemental medwatch report will be sent accordingly.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Additional Manufacturer Narrative
This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by mitek or its employees that the report constitutes an admission that the device, mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.H10 additional narrative: investigation summary: the complaint device was received and evaluated.Upon visual inspection, it was found the device was not inside its original packaging, the anchor was broken while the sutures were not returned.A manufacturing record evaluation was performed for the finished device (b)(6) number, and no non-conformances were identified.As part of depuy synthes mitek quality process all devices are manufactured, inspected, and released to approved specifications.According with the visual inspection, this complaint can be confirmed.The investigation was performed by the manufacturing department with the following results: an in-process control has been performed on 9 parts chosen randomly by a certified operator and were inspected.The result of this process check was successful, none of the 9 parts were non-conformed.So there was no need to inspect more parts of the batch nor raise a non-conformance.According to product manufacturing process; the potential occurrence of having a broken suture has been evaluated to 0 over 16343 ea since 2016 corresponding to defect over parts.The presence of a deformed needle is already identified in the product manufacturing process.Effect of having packing anchor deformed & packing anchor breakage has been evaluated in the product manufacturing process by combining probability and severity levels.With a ratio of 0% < 0.02% and is ranking 1 (= improbable and negligible).This risk is acceptable.A complaint research, with the same defect did not show another case with this issue from 2019 to now with the items reference 210709.No nr was found during the research.Based on the above, it is confirmed that the manufacturing process has been performed according to the validated processes.The bounding is limited on this part as the complaint analysis shows that there is no other occurrence of such defect for this batch, the batch before and the batch after.A manufacturing investigation activity has been performed to determine if there were any internal processing issues which would have contributed to the nature of the product complaint.There has been a closer look on the in-process controls.The results indicate that this batch of product was processed without incident; therefore, there is no evidence of manufacturing anomalies on the document reviewed.Its been confirmed that the product is 100% visual inspected, also, the personnel involved in the process are completely certified in their activities.According with the investigation results, we can conclude this issue to be an isolated case.At this point in time, no corrective action is required, and no further action is warranted.However, depuy synthes mitek will continue to monitor additional complaint information for potential safety signals through complaint trending as part of post market surveillance.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LUPINELOOPPLUS ANCHOR W/OC DS
Common Device Name
SOFT-TISSUE ANCHOR, BIOABSORBABLE
Manufacturer (Section D)
DEPUY MITEK LLC US
325 paramount drive
raynham MA 02767
Manufacturer (Section G)
MEDOS INTERNATIONAL SARL
chemin blanc 38
le locle CH-24 00
SZ   CH-2400
Manufacturer Contact
kara ditty-bovard
325 paramount drive
raynham, MA 02767
6013142063
MDR Report Key12923007
Report Number1221934-2021-03563
Device Sequence Number20225976
Product Code MAI
UDI-Device Identifier10886705001071
UDI-Public10886705001071
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K150209
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup,Followup
Report Date (Section B) 11/19/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/31/2023
Device Model Number210709
Device Catalogue Number210709
Device Lot Number7L02705
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/03/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/19/2021
Supplement Date Received by Manufacturer12/27/2021
01/03/2022
01/17/2022
Initial Report FDA Received Date12/03/2021
Supplement Report FDA Received Date12/28/2021
01/04/2022
01/18/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured06/12/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-