• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: AESCULAP AG CRANIOPLATE 1.5 SCR.MAG.CROSS L:4MM; CRANIAL FIXATION

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

AESCULAP AG CRANIOPLATE 1.5 SCR.MAG.CROSS L:4MM; CRANIAL FIXATION Back to Search Results
Model Number FM921T
Medical Device Problem Code Material Fragmentation (1261)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 10/09/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Manufacturing site evaluation: investigation on-going.Should relevant additional information / investigation results become available, a supplemental medwatch report will be submitted.
 
Event or Problem Description
It was reported to aesculap ag that a cranioplate 1.5 scr.Mag.Cross l:4mm (part # fm921t) was used during a procedure performed on (b)(6) 2021.According to the complainant, during the procedure, the screw was broken.The complaint device was not returned to the manufacturer for evaluation.No patient complications were reported as a result of the event.Although requested, additional information has not been made available.The malfunction is filed under aag reference (b)(4).
 
Additional Manufacturer Narrative
Visual investigation: 30 screws with broken off tip and deformations arrived for investigation.The broken off tips were not enclosed.Investigation was carried out visually and microscopically.All screws show damage.These are pronounced to different degrees on all screws.They are in detail: damaged threads, damaged phillips screw heads, broken screw tips and deformations.The fracture surface of the broken off tips show the typical signs of a screw that was torn off by excessive torque.The phillips heads show significant wear and deformation.Without further knowledge about the circumstances we suspect that the surgeon made some handling errors during implantation.The ifu points out to consider some points during handling and implantation.Due to the constant monitoring of the compliance with our quality standards, as matters stand, a production or material defect can most likely be excluded.Batch history review: the device quality and manufacturing history records have been checked for the available lot number and were found to be according to our specifications valid at the time of production.Review of the complaint history revealed that no similar complaints have been filed against products from this batch number.The review of risk assessment revealed that the overall risk level (severity 5(10) x probability of occurrence 7(10) according to din en iso 14971 is still acceptable.Conclusion and measures / preventive measures: based upon the investigation results a clear root cause conclusion cannot be drawn.There is no indication for a material-, manufacturing- or design-related failure.Based upon the investigations results a capa is not necessary.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CRANIOPLATE 1.5 SCR.MAG.CROSS L:4MM
Common Device Name
CRANIAL FIXATION
Manufacturer (Section D)
AESCULAP AG
po box 40
tuttlingen, 78501
GM  78501
Manufacturer (Section G)
AESCULAP AG
po box 40
tuttlingen, 78501
GM   78501
Manufacturer Contact
christian von der grün
po box 40
tuttlingen, 78501
GM   78501
MDR Report Key12924539
Report Number9610612-2021-00767
Device Sequence Number5476026
Product Code JEY
UDI-Device Identifier04038653463671
UDI-Public4038653463671
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K060492
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 12/31/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberFM921T
Device Catalogue NumberFM921T
Device Lot Number52694252
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/08/2021
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/10/2021
Supplement Date Received by Manufacturer12/07/2021
Initial Report FDA Received Date12/03/2021
Supplement Report FDA Received Date12/31/2021
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/26/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-