Model Number PRPR0006
Health Effect - Clinical Codes Pain (1994); Loss of Range of Motion (2032)
Date of Event 10/19/2021
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
This event will be updated once the investigation is complete.Trends will be evaluated.
 
Event or Problem Description
Allegedly, patient experienced a sudden onset of pain in the hip joint with subsequent buckling of the leg during normal walking the previous day.Radiological examination revealed a cone fracture.
 
Additional Manufacturer Narrative
Due to additional information received from microport orthopedics reliability engineer and further analysis, it's considered that the product listed on this report as productid: prpr0006 profemur preserve stem , lot no: 1553951 ; should be changed to "no complaint stated" since there's no complaint against this device.Please void this report.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PROFEMUR® PRESERVE STEM SIZE 6
Common Device Name
HIP COMPONENT
Manufacturer (Section D)
MICROPORT ORTHOPEDICS INC.
5677 airline rd.
arlington TN 38002
Manufacturer (Section G)
MICROPORT ORTHOPEDICS INC.
5677 airline rd.
arlington TN 38002
Manufacturer Contact
5677 airline road
arlington, TN 38002
9018674771
MDR Report Key12957517
Report Number3010536692-2021-00580
Device Sequence Number1792811
Product Code JDL
UDI-Device IdentifierM684PRPR00061
UDI-PublicM684PRPR00061
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K112080
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2015
Device Explanted Year2021
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 12/16/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Other
Device Model NumberPRPR0006
Device Catalogue NumberPRPR0006
Device Lot Number1553951
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Distributor Facility Aware Date11/16/2021
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/16/2021
Supplement Date Received by Manufacturer11/16/2021
Initial Report FDA Received Date12/07/2021
Supplement Report FDA Received Date12/16/2021
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age63 YR
Patient SexMale
Patient Weight85 KG
-
-