|
The reported event could not be confirmed.No sample was returned for evaluation.Based on the investigation findings, current manufacturing controls are considered adequate as to detect and segregate any non-conforming unit.Event described could not be confirmed as a manufacturing related issue.The alleged event is most likely associated with possible procedural/surgical complications.The ifu currently addresses potential risks associated with surgically implantable materials which states the following: precautions: the usual precautions associated with urological procedures should be followed: accepted surgical practice and precautions must be followed for the management of contaminated or infected wound sites, when the align¿ urethral support system is used.Postoperative retropubic bleeding may occur in some patients and must be controlled prior to patient release.The implant procedure requires diligent attention to anatomical structure and care to avoid puncture of large vessels, nerves, bladder, and any viscera, during introducer needle passage.Cystoscopy should be performed to confirm bladder integrity or recognize a bladder perforation.Proper placement of the mesh sling implant at mid-urethra requires that it lies flat with minimal or no tension under the urethra.The align¿ urethral support system is intended as a single-use, disposable device.Do not resterilize any portion of the align¿ urethral support system.Patients should be advised that pregnancy following a mesh sling implant procedure may negatively affect the success of the previous implant procedure and incontinence may reoccur.The safety and effectiveness of the align¿ urethral support system implant procedure has not been established for the treatment of stress urinary incontinence in males or children under the age of 18.Do not use the align¿ urethral support system if the packaging is opened or damaged.After use, this product may be a potential biohazard.Handle and dispose of in accordance with accepted medical practice and applicable local, state and federal laws and regulations.Adverse events: complications associated with the proper implantation of the align¿ urethral support system may include, but are not limited to: postoperative hematoma, which may occur following the implant procedure temporary urinary retention, bladder outlet obstruction, and voiding difficulties associated with over-correction/too much tension placed on the mesh sling implant perforations or lacerations of vessels, nerves, bladder or any viscera, which may occur during introducer needle passage transitory irritation at the operative wound site, which may elicit a foreign body response that leads to inflammation, infection, or erosion of the implant.1750="l".2348, 2119, 2993="nl".
|
|
The patient's attorney alleged a deficiency against the device.Additional information has been requested, but not yet received.Per additional information received on 22nov2021, the patient has experienced urinary retention, mesh erosion into the urethra, stress urinary incontinence, rectal prolapse, difficulty in voiding, and required additional surgical and non-surgical interventions.
|