| Model Number |
FDS40017 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Hyperplasia (1906); Stenosis (2263)
|
| Date of Event |
11/11/2021
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
The subject device is unavailable to manufacturer.
|
| |
|
Event or Problem Description
|
|
It was reported that on the patient follow up, it was determined that the patient developed endoluminal intimal hyperplasia.The location of the implant was in the vasculature ica (internal carotid artery).Upon multi physician conference, it was suggested that the subject surpass evolve stent could be the cause.The patient¿s current condition is asymptomatic and there was not any mechanical injury to artery at the location of the hyperplasia via angiography.No other information was provided.
|
| |
|
Additional Manufacturer Narrative
|
|
B2 adverse event/product problem - corrected : no 'product problem'.B2 outcomes attributed to ae - corrected - no 'hospitalization-initial or prolonged '.Although the dhr (device history record) could not be reviewed because the lot number for the surpass evolve remains unknown, there are controls in the manufacturing process to ensure the product met specifications upon release.The subject device was not available; therefore, a visual inspection as well as a functional evaluation could not be performed.The reported event is covered in the device directions for use (dfu).As well, the risk of the reported event is documented in the risk documentation and there are current controls to mitigate the risk of the as reported event.It was reported on the patient follow up, the patient developed endoluminal intimal hyperplasia.Based upon medical review, the harm observed in this complaint is anticipated in nature as per the device risk assessment.As a product related root cause does not apply and the issue is due to a known physiological effect of the procedure and/or patient condition noted within the dfu, product labeling and/or risk documentation files, an assignable cause of anticipated procedural complication will be assigned to this complaint.
|
| |
|
Event or Problem Description
|
|
It was reported that on the patient follow up, it was determined that the patient developed endoluminal intimal hyperplasia.The location of the implant was in the vasculature ica (internal carotid artery).Upon multi physician conference, it was suggested that the subject surpass evolve stent could be the cause.The patient¿s current condition is asymptomatic and there was not any mechanical injury to artery at the location of the hyperplasia via angiography.No other information was provided.
|
| |
|