| Model Number |
4400604S |
| Medical Device Problem Code |
Burst Container or Vessel (1074)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
11/17/2021
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
As reported, the balloon of a powerflex pro 6mm 4cm 80 ruptured.There was no reported injury to the patient.The device will not be returned for evaluation as it was discarded.The lesion to be treated was in the iliac artery.
|
| |
|
Additional Manufacturer Narrative
|
|
A review of the manufacturing documentation associated with lot 82220667 presented no issues during the manufacturing process that can be related to the reported event.Additional information is pending and will be submitted within 30 days upon receipt.
|
| |
|
Event or Problem Description
|
|
As reported, the balloon of a powerflex pro 6mm 4cm 80 ruptured.There was no reported injury to the patient.The device will not be returned for evaluation as it was discarded.The lesion to be treated was in the iliac artery.Additional information was requested; however, the information could not be obtained.
|
| |
|
Additional Manufacturer Narrative
|
|
As reported, the balloon of a powerflex pro 6mm 4cm 80 percutaneous transluminal angioplasty (pta) balloon catheter ruptured.There was no reported injury to the patient.The lesion to be treated was in the iliac artery.Additional information was requested; however, the information could not be obtained.The product was not returned for analysis as it was discarded.A product history record (phr) review of lot 82220667 revealed no anomalies or non-conformances during the manufacturing and inspection processes that can be associated with the reported event.The reported ¿balloon burst¿ could not be confirmed as the device was not returned for analysis.The exact cause could not be determined.Vessel characteristics, although unknown, may have contributed to the reported event.However, with the limited amount of information provided and without the return of the device for analysis, it is difficult to draw a clinical conclusion between the device and the event reported.According to the safety information in the instructions for use, ¿if resistance is met during manipulation, determine the cause of the resistance before proceeding.Balloon pressure should not exceed the rated burst pressure.The rated burst pressure is based on the results of in vitro testing.(b)(4).Use of a pressure monitoring device is recommended to prevent over pressurization.Use only the recommended balloon inflation medium.Never use air or any gaseous medium to inflate the balloon.Prior to angioplasty, the catheter should be examined to verify functionality and ensure that its size and shape are suitable for the specific procedure for which it is to be used.¿ neither the phr nor the information available suggests a design or manufacturing related cause for the reported event.Therefore, no corrective or preventive action will be taken at this time.
|
| |
|