|
Model Number U415034RX |
Device Problem
Material Rupture (1546)
|
Patient Problem
No Clinical Signs, Symptoms or Conditions (4582)
|
Event Date 11/24/2021 |
Event Type
malfunction
|
Manufacturer Narrative
|
As the lot number for the device was provided, a review of the device history records will be performed.The sample was not returned to the manufacturer for inspection/evaluation.Therefore, the investigation of the reported event is inconclusive.Based upon the available information, the definitive root cause for this event is unknown.The instructions for use (ifu) is adequate for the reported device/patient code(s) and provides general instructions for use, as well as warnings, precautions and potential complications associated with the device.Upon receipt of new or additional information, a follow-up report will be submitted as applicable.Expiry date: 12/2023.
|
|
Event Description
|
It was reported that during an angioplasty procedure of a highly calcified target lesion in the left anterior tibial artery via an ipsilateral antegrade approach, the pta balloon allegedly ruptured under nominal pressure.There was no reported patient injury.
|
|
Manufacturer Narrative
|
H10: the file was reassessed for reportability and determined to be no longer reportable.Since an initial mdr was submitted, therefore, the file will remain assessed as a malfunction.H10: d4 (expiry date: 12/2023), g3.H11:section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : device not returned.
|
|
Event Description
|
It was reported that during an angioplasty procedure of a highly calcified target lesion in the left anterior tibial artery via an ipsilateral antegrade approach, the pta balloon allegedly ruptured under nominal pressure.There was no reported patient injury.
|
|
Search Alerts/Recalls
|
|
|