ABBOTT DIABETES CARE INC FS PREC PRO-CODING; BLOOD GLUCOSE MONITORING SYSTEM Back to Search Results
Model Number 71284-70
Medical Device Problem Code Incorrect, Inadequate or Imprecise Result or Readings (1535)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/30/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The product has been requested back for investigation.A follow-up report will be submitted once additional information is obtained.All pertinent information available to abbott diabetes care has been submitted.
 
Event or Problem Description
A customer reported receiving erroneous glucose results from an abbott diabetes care device.The results when plotted on a parkes error grid fell into either the c, d, or e zone.There was no report of death, serious injury, or mistreatment associated with this event.
 
Additional Manufacturer Narrative
Repeated attempts by adc to retrieve the product were unsuccessful and/or the customer discarded the product.No product has been returned.An extended investigation has been performed for the reported complaint and it has been determined that there was no indication that the product did not meet specifications.The dhrs for the freestyle precision pro meter was reviewed.The dhrs showed the freestyle precision pro meter passed all tests prior to release.The dhrs (device history review) for the precision strips was reviewed.The dhrs showed the precision strips passed all tests prior to release.Retain testing was performed for precision strips and all units performed in specification and passed.If the product is returned, the case will be re-opened, and a physical investigation will be performed.All pertinent information available to abbott diabetes care has been submitted.
 
Event or Problem Description
A customer reported receiving erroneous glucose results from an abbott diabetes care device.The results when plotted on a parkes error grid fell into either the c, d, or e zone.There was no report of death, serious injury, or mistreatment associated with this event.
 
Additional Manufacturer Narrative
The returned meter was investigated with a known-good retained battery.Visual inspection was performed on returned meter and no issues were observed.Inserted retain batteries into the meter.Meter powered on with button depression.Lcd was observed to be powered up/ self-test sequence and no issues observed.Control solution testing was performed and all results are within specification.No issues were observed with returned meter.Therefore this issue is not confirmed.The strip has been requested back for an investigation and the customer agreed to return the device.However, strip has been received at this time despite follow up attempts by adc.If the partial product is returned, a physical investigation will be performed per adc's established processes and procedures and a report will be submitted upon completion of investigation.All pertinent information available to abbott diabetes care has been submitted.
 
Event or Problem Description
A healthcare professional reported a low reading from an abbott diabetes care blood glucose hospital meter.The healthcare professional reported a low blood glucose reading of 35 mg/dl compared to an abbott diabetes care blood glucose meter reading of 202 mg/dl.When plotted on a parkes error grid, the results fall in the c zone showing the difference in values to be clinically significant.There was no report of death, serious injury, or mistreatment associated with this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FS PREC PRO-CODING
Common Device Name
BLOOD GLUCOSE MONITORING SYSTEM
Manufacturer (Section D)
ABBOTT DIABETES CARE INC
1360 south loop road
alameda CA 94502 7001
Manufacturer Contact
audra fuentes
1360 south loop road
alameda, CA 94502-7001
5107495297
MDR Report Key13052394
Report Number2954323-2021-96249
Device Sequence Number19189346
Product Code NBW
UDI-Device Identifier00093815714118
UDI-Public(01)00093815714118(10)01Z232D
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K132511
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Consumer
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 02/17/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date07/31/2022
Device Model Number71284-70
Device Catalogue Number71284
Device Lot Number8A63P0
Was Device Available for Evaluation? Device Returned to Manufacturer
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/30/2021
Supplement Date Received by Manufacturer01/05/2022
01/28/2026
Initial Report FDA Received Date12/21/2021
Supplement Report FDA Received Date01/10/2022
02/17/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/15/2019
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient SexUnknown
-
-