• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ARTHREX, INC. UNIVERSAL GLENOID - INLAY MEDIUM; SHOULDER PROSTHESIS, REVERSE CONFIGURATION

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARTHREX, INC. UNIVERSAL GLENOID - INLAY MEDIUM; SHOULDER PROSTHESIS, REVERSE CONFIGURATION Back to Search Results
Model Number UNIVERSAL GLENOID - INLAY MEDIUM
Health Effect - Clinical Codes Pain (1994); Loss of Range of Motion (2032); Osteolysis (2377)
Date of Event 02/13/2020
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that a revision surgery was performed on the (b)(6) 2020 due to polyethylene abrasion in combination with metallosis and osteolysis.The initial surgery took place in (b)(6) 2016.From summer 2019 on the patient suffered from pain, restriction of shoulder movement, and a strong squeaking noise occurred when moving the shoulder.During the revision surgery it was noticed that the devices didn`t show any sign of loosening and the position was still correct.The polyethylene part of the device showed a high pe consumption and is massively thinned out.In the free joint space, a broken off part of the polyethylene was found.Osteolysis could be observed at the upper glenoid pole of approx.One cubic centimeter to the proximal screw caused by the metallosis.The patient was treated by replacing the polyethylene inlay with a new one of size medium.Removal of the old an application of a new anti-allergenic eclipse dome as usual of size 47/16.In addition a resection of any metallic altered soft tissue as well as synovial tissue was performed.The surgery was finished successfully.The patient reports a permanent limitation of movement since the incident.
 
Additional Manufacturer Narrative
The contribution of the device to the reported event could not be determined as the device was not returned for evaluation.The root cause of the event could not be determined from the information available and without device evaluation.If the device becomes available for evaluation, a follow-up report will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNIVERSAL GLENOID - INLAY MEDIUM
Common Device Name
SHOULDER PROSTHESIS, REVERSE CONFIGURATION
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
vik bajnath
8009337001
MDR Report Key13053843
Report Number1220246-2021-04127
Device Sequence Number1426898
Product Code PHX
UDI-Device Identifier00888867057425
UDI-Public00888867057425
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K182039
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 12/21/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date04/30/2017
Device Model NumberUNIVERSAL GLENOID - INLAY MEDIUM
Device Catalogue NumberAR-9121-02
Device Lot Number2501210204
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/30/2021
Initial Report FDA Received Date12/21/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-