Product complaint # (b)(4).(b)(4).Device not returned.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Attempts have been made to retrieve the device.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.The following information was requested, but unavailable: what tissue was being approximated or sutured when it broke? no further information is available.Patient condition? no further information is available.What was used to complete the procedure? no further information is available.A manufacturing record evaluation was performed for the finished device lot, and no non-conformances were identified.
|
|
Product complaint # (b)(4).Date sent to the fda: 02/24/2022.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon inc, or its employees that the report constitutes an admission that the product, ethicon inc or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.H3 investigation summary: one empty labeled winding former, a needle and a suture product code j506 were returned for analysis.Upon visual analysis of the returned sample revealed that clip off defect was observed in the sample.The barrel hole was examined under 20x magnification and revealed a remnant suture.In addition, the extreme suture was noted to be severely cut.As per returned conditions of the sample no functional test was performed.This defect is caused by excessive pressure on the suture during swaging of the needle and consequently breaking.Based on the information currently available, the clip off was identified during the investigation of the sample received.This product issue will be addressed through quality system.Additional complaint information monitoring for potential safety signals will be conducted through complaint trending as part of post-market surveillance.,according to the information received, it was reported that the problem of pulling off suture needle had happened in plastic and cosmetic surgery.Two packets of product code j506 were returned to ethicon inc for analysis with the packaging closed.Upon initial inspection to the samples no external damages were observed on the packets.In order to evaluate the conditions of the returned samples, the packets were opened, and no defects were detected.The swage and attachment area were noted to be as expected.The sutures were dispensed without problems and examined along of the strand to detect any issue related to damaged or breakage suture and no defects were observed during evaluation.Functional test was performed, and the tensile strength results were above the minimum requirements.As part of our quality process, the manufacturing records of this lot-serial number were reviewed, and the manufacturing standards were met prior to the release of this batch.As part of quality process, all devices are manufactured, inspected, and released to approved specifications.There may have been other circumstances or issues that occurred during the use of the device that we were unable to duplicate during our laboratory analysis.
|