The device was received, the investigation is in progress, no conclusion could be drawn at the time of filing this report.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H3, h6: a product investigation was conducted.Visual inspection: the complaint device rod cutter 3.5 and 4.0 rods (product code: 202000135, lot number: gs676412) was returned to cq west chester for investigation.The rod cutter had a crack starting from the jaw to the opening for the 4.0 mm rods.Also, the etch on the item was fading.The item was discolored.Document /specification review: based on the date of manufacture, the current and manufactured version of the drawings were reviewed.Dimensional inspection: complaint relevant dimension could not be measured due to the design of the device.Complaint can be confirmed based on the available information.Conclusion: the rod cutter had a crack on its jaw and was discolored.A definitive root cause was not determined during investigation.There was no indication that a design or manufacturing issue contributed to the complaint.No design issues were observed during the document/specification review.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.H3, h6: a device history record (dhr) review was conducted: a review of the receiving inspection (ri) for rod cutter 3.5 and 4.0 rods was conducted identifying that lot number gs676412 was released in two (2) batches.Batch1: lot qty of 212 units were released on oct 28, 2019 with no discrepancies.Batch2: lot qty of 1 units were released on dec 5, 2019 with no discrepancies.As a result, the ri identified no issues during the manufacturing and release of this device that could have contributed to the problem reported by the customer.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|