| Catalog Number |
0112650 |
| Medical Device Problem Codes |
Defective Device (2588); Patient-Device Incompatibility (2682); Patient Device Interaction Problem (4001)
|
| Health Effect - Clinical Codes |
Adhesion(s) (1695); Unspecified Infection (1930); Pain (1994); Scar Tissue (2060); Insufficient Information (4580)
|
| Date of Event |
08/26/2021
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
No conclusions can be made.The patient's attorney alleges "past, present, and future damages, including but not limited to, mental and physical pain and suffering for severe and permanent personal injuries sustained by the patient"; however, no details have been provided.No lot number has been provided; therefore, a review of the manufacturing records is not possible.Should additional information be provided, a supplemental emdr will be submitted.Not returned.
|
| |
|
Event or Problem Description
|
|
Attorney alleges that the patient underwent surgery for implant of an unspecified bard mesh (bard flat mesh) on (b)(6) 2021.As reported, the patient is making a claim for an adverse patient outcome against the bard mesh (bard flat mesh).Attorney alleges general allegations for "past, present, and future damages, including but not limited to, mental and physical pain and suffering for severe and permanent personal injuries sustained by the patient.¿ it is also alleged that the patient experienced emotional distress and the device was defective.
|
| |
|
Event or Problem Description
|
|
Attorney alleges that the patient underwent surgery for implant of an unspecified bard mesh (bard flat mesh) on (b)(6)2021.As reported, the patient is making a claim for an adverse patient outcome against the bard mesh (bard flat mesh).Attorney alleges general allegations for "past, present, and future damages, including but not limited to, mental and physical pain and suffering for severe and permanent personal injuries sustained by the patient.¿ it is also alleged that the patient experienced emotional distress and the device was defective.Addendum per additional information provided:
(b)(6)2021 - patient was diagnosed with left inguinal hernia thereby underwent open repair with the implant of bard flat mesh.Per op notes, "an incision was made carried over the left inguinal canal.The bard flat mesh was placed to the floor of the canal using sutures."
(b)(6)2021 - patient was diagnosed with infected mesh thereby underwent repair with removal of infected mesh.Per op notes, "an incision was made around the left inguinal region.There was a draining sinus in the middle of an old scar.Began to excise mesh from adherent tissue and the mesh was removed.A biologic mesh was placed.".
|
| |
|
Additional Manufacturer Narrative
|
|
No conclusions can be made.The patient's attorney alleges "past, present, and future damages, including but not limited to, mental and physical pain and suffering for severe and permanent personal injuries sustained by the patient"; however, no details have been provided.No lot number has been provided; therefore, a review of the manufacturing records is not possible.Addendum:
this supplemental emdr is submitted to document additional information provided.Root cause is inconclusive, no conclusion can be made as to the extent to which the implant may have caused or contributed to the patient's postoperative course.Note, the manufacturing date (15-jan-2020) is considered to be a best estimate.Updated fields: a2, a4, b2, b3, b4, b5, b7, d3, d4 (product lot no., product catalog no., expiry date, udi no), d.6b (date of explant), g3, g6, h2, h4, h6, h10.Note: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Search Alerts/Recalls
|
|
|