• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: LUTONIX, INC LUTONIX 018 DRUG COATED DILATATION CATHETER; DRUG COATED PTA BALLOON CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

LUTONIX, INC LUTONIX 018 DRUG COATED DILATATION CATHETER; DRUG COATED PTA BALLOON CATHETER Back to Search Results
Model Number 9014
Medical Device Problem Codes Difficult to Insert (1316); Material Twisted/Bent (2981)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/06/2021
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that during an angioplasty procedure through the groin femoral to treat the sfa via a contralateral approach, the balloon allegedly twisted upon inflation.It was further reported that balloon was removed form patient and tried to insert again, however, the balloon was allegedly unable to insert.There was no reported patient injury.
 
Additional Manufacturer Narrative
As the lot number for the device was provided, a review of the device history records is currently being performed.The device has not been returned to the manufacturer for evaluation.However, a photo and image were provided for review.The investigation of the reported event is currently underway.Expiry date: 04/2023.
 
Additional Manufacturer Narrative
H10: manufacturing review: a manufacturing review was not required as this is the only complaint reported to date for this product and lot.Investigation summary: the physical device was not returned for evaluation.One medical image was reviewed.A fluoroscopy image is reviewed showing the lutonix 018 balloon inflated along a segment likely of the left superficial femoral artery.Towards the bottom of the screen it appears that a small portion of the balloon is not inflated, which is a represented by a small ¿waist¿ or narrowing of the balloon.Based on the image review, material twisted can be confirmed.However difficult to insert is kept inconclusive.One photo was provided and reviewed.The photo shows the lutonix 018 balloon which appears bloody.No twisting is seen on the balloon.No other specific anomalies noted.Therefore, material twisted and difficult to insert is kept inconclusive based on the submitted photo.Therefore, the investigation is confirmed for the reported material twisted since material twisting was noted on the balloon during medical image review.However, the investigation is inconclusive for the reported difficult to insert as no objective evidence was provided for review.A definitive root cause for the alleged material twisted and difficult to insert could not be determined based upon the provided information.Labeling review: a review of product labeling documentation (e.G., procedural instructions, indications, warnings, precautions, cautions, possible complications, contraindications, nursing guide, and unit label) did not find any product labeling inadequacy.H10: d4(expiry date: 04/2023).H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : device not returned.
 
Event or Problem Description
It was reported that during an angioplasty procedure through the groin femoral to treat the sfa via a contralateral approach, the balloon allegedly twisted upon inflation.It was further reported that balloon was removed form patient and tried to insert again, however, the balloon was allegedly unable to insert.There was no reported patient injury.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LUTONIX 018 DRUG COATED DILATATION CATHETER
Common Device Name
DRUG COATED PTA BALLOON CATHETER
Manufacturer (Section D)
LUTONIX, INC
9409 science center dr
new hope 55428
Manufacturer (Section G)
C.R. BARD, INC. (GFO)
289 bay road
queensbury 12804
Manufacturer Contact
judy ludwig
800 w. rio salado pkwy
tempe, AZ 85281
4803032689
MDR Report Key13151450
Report Number3006513822-2021-00061
Device Sequence Number5412258
Product Code ONU
UDI-Device Identifier00801741184710
UDI-Public(01)00801741184710
Combination Product (Y/N)N
Initial Reporter StateMO
Initial Reporter CountryUS
PMA/510(K) Number
P130024
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other,Health Professional,User Facility,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 01/11/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number9014
Device Catalogue NumberLX1813053005F
Device Lot NumberGFFQ0625
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 12/07/2021
Supplement Date Received by Manufacturer01/11/2022
Initial Report FDA Received Date01/04/2022
Supplement Report FDA Received Date01/17/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-