MAUDE Adverse Event Report: MEDTRONIC, INC LAUNCHER 7F GUIDE CATHETER; CATHETER, PERCUTANEOUS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDTRONIC, INC LAUNCHER 7F GUIDE CATHETER; CATHETER, PERCUTANEOUS Back to Search Results
Model Number LA7JL35
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Perforation (2001); Obstruction/Occlusion (2422); Vascular Dissection (3160); Thrombosis/Thrombus (4440)
Date of Event 12/06/2021
Type of Reportable Event Serious Injury
Event or Problem Description
An attempt was made to use two launcher guide catheters to treat a severely tortuous, moderately calcified lesion with 100% cto (chronic total occlusion) in the mid left anterior descending (lad) artery and circumflex (cx) artery.The device was inspected with no issues noted.Negative prep was performed with no issues.Resistance was encountered when advancing the device.Excessive force was used during delivery.The lesion was also treated with three non-medtronic guidewires, a non-medtronic balloon and a non-medtronic cutting balloon.A non-medtronic micro catheter was also used during the procedure.It was reported that a vessel occlusion occurred due to a device component.It was also reported that thrombosis/clots occurred after the procedure in the lad.The physician suggested the adverse event is device related, as clot has occurred after the use of the launcher during the procedure.The patient was on dapt at the time of the event.The event was treated with anti thrombolytic agents.No further patient injury as reported.
 
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Additional Manufacturer Narrative
Additional information received: the 100% cto (chronic total occlusion) was caused by a fibrotic lesion.It was reported that dissection and perforation occurred during the procedure in the lad.It t was suggested the vessel occlusion to be caused by thrombosis/clots noted during ecg and coronary angiogram, during the procedure.The physician suggested the adverse events are due to a device component.Correction: both devices were inspected with no issues noted.Resistance was encountered for both devices.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Additional Manufacturer Narrative
Additional information: fdc code added correction: fdr code added.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Additional Manufacturer Narrative
Product analysis: the lot number matches details in the complaint file.One 7 fr launcher guide catheter was received for analysis.Guide catheter was flushed before decontamination with no evidence of thrombus or foreign material inside the device.A 0.035 inch guidewire was loaded through the lumen with no resistance noted.No damage was noted to the distal tip.No other damage was noted to the remainder of the device.Correction: negative prep was not performed on the launcher devices.Instead the devices were prepped per ifu with no issues.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LAUNCHER 7F GUIDE CATHETER
Common Device Name
CATHETER, PERCUTANEOUS
Manufacturer (Section D)
MEDTRONIC, INC
37a cherry hill dr
danvers MA 01923
Manufacturer (Section G)
MEDTRONIC, INC
37a cherry hill dr
danvers MA 01923
Manufacturer Contact
alison sweeney
parkmore business park west
galway 
EI  
091708096
MDR Report Key13151536
Report Number1220452-2022-00001
Device Sequence Number4079018
Product Code DQY
UDI-Device Identifier00613994832092
UDI-Public00613994832092
Combination Product (Y/N)N
Initial Reporter CountryIN
PMA/510(K) Number
K022764
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup,Followup
Report Date (Section B) 03/29/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date03/03/2023
Device Model NumberLA7JL35
Device Catalogue NumberLA7JL35
Device Lot Number0010588356
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/06/2021
Supplement Date Received by Manufacturer01/10/2022
03/14/2022
03/28/2022
Initial Report FDA Received Date01/04/2022
Supplement Report FDA Received Date01/17/2022
03/23/2022
03/29/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured03/03/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient Age69 YR
Patient SexMale
-
-