| Model Number |
KD-655Q |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Unspecified Infection (1930); Perforation (2001)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
The subject device was not returned to olympus.Therefore, the exact cause of the reported event could not be conclusively determined.Since the lot number is unknown, the device history record could not be reviewed.However, omsc has only shipped devices that passed the inspection.In the literature, there was no description of the device's malfunction.
|
| |
|
Event or Problem Description
|
|
On december 22, olympus medical systems corp.(omsc) received the literature "high total joule heat increases the risk of post-endoscopic submucosal dissection electrocoagulation syndrome after colorectal endoscopic submucosal dissection¿.The purpose of the literature was to determine the association between joule heat and the onset of post-esd electrocoagulation syndrome (pecs).The endoscopic submucosal dissection (esd) was performed using a water-jet system colonoscope (pcf-q260ji), a dual knife (kd-655q), a coagrasper (fd-411qr) and an endoscopic clip (hx-610-090).A transparent hood was manufactured by non-olympus.In the literature, it was reported 7 cases of intraoperative perforation or penetration, 2 cases of infectious disease after colorectal esd, 16 cases of pecs, 45 cases of submucosal fibrosis, and 12 case of additional surgery after esd.There was no more information of 7 cases of intraoperative perforation or penetration, 2 cases of an infectious disease after colorectal esd, 45 cases of submucosal fibrosis, and 12 case of additional surgery after esd.The literature wrote, ¿pecs is a state of temporary inflammation resulting from transmission of electrocoagulation heat to the resection site muscle layer and serous membrane during endoscopic therapy[18,25,26].Previously reported pecs risk factors include tumor location[11,13,20,27], sm fibrosis[27], long procedure time[20,21], and specimen diameter[11,13].Long procedures lead to the occurrence of pecs due to increased electrical current load on the gastrointestinal wall[11].Additionally, ischemic changes occur in the gastrointestinal wall due to excessive current during incision, dissection, and hemostasis[28].These reports suggest that joule heat of the peeled mucosal surface is associated with the occurrence of pecs¿.Based on the available information, no malfunction was reported and a direct relationship between the olympus product and these complications could not be determined.However, 7 cases of intraoperative perforation or penetration, 2 cases of infectious disease after colorectal esd, and 12 case of additional surgery after esd might be serious injury, and the olympus knife might be associated with these complications.This is the report regarding 7 cases of intraoperative perforation or penetration, 2 cases of infectious disease after colorectal esd, and 12 case of additional surgery after esd.
|
| |
|
Additional Manufacturer Narrative
|
|
The subject device was not returned to olympus.Therefore, the exact cause of the reported event could not be conclusively determined.Since the lot number is unknown, the device history record could not be reviewed.However, omsc has only shipped devices that passed the inspection.In the literature, there was no description of the device's malfunction.
|
| |
|
Event or Problem Description
|
|
On december 22, olympus medical systems corp.(omsc) received the literature "high total joule heat increases the risk of post-endoscopic submucosal dissection electrocoagulation syndrome after colorectal endoscopic submucosal dissection¿.The purpose of the literature was to determine the association between joule heat and the onset of post-esd electrocoagulation syndrome (pecs).The endoscopic submucosal dissection (esd) was performed using a water-jet system colonoscope (pcf-q260ji), a dual knife (kd-655q), a coagrasper (fd-411qr) and an endoscopic clip (hx-610-090).A transparent hood was manufactured by non-olympus.In the literature, it was reported 7 cases of intraoperative perforation or penetration, 2 cases of infectious disease after colorectal esd, 16 cases of pecs, 45 cases of submucosal fibrosis, and 12 case of additional surgery after esd.There was no more information of 7 cases of intraoperative perforation or penetration, 2 cases of an infectious disease after colorectal esd, 45 cases of submucosal fibrosis, and 12 case of additional surgery after esd.The literature wrote, ¿pecs is a state of temporary inflammation resulting from transmission of electrocoagulation heat to the resection site muscle layer and serous membrane during endoscopic therapy[18,25,26].Previously reported pecs risk factors include tumor location[11,13,20,27], sm fibrosis[27], long procedure time[20,21], and specimen diameter[11,13].Long procedures lead to the occurrence of pecs due to increased electrical current load on the gastrointestinal wall[11].Additionally, ischemic changes occur in the gastrointestinal wall due to excessive current during incision, dissection, and hemostasis[28].These reports suggest that joule heat of the peeled mucosal surface is associated with the occurrence of pecs¿.Based on the available information, no malfunction was reported and a direct relationship between the olympus product and these complications could not be determined.However, 7 cases of intraoperative perforation or penetration, 2 cases of infectious disease after colorectal esd, and 12 case of additional surgery after esd might be serious injury, and the olympus knife might be associated with these complications.This is the report regarding 7 cases of intraoperative perforation or penetration, 2 cases of infectious disease after colorectal esd, and 12 case of additional surgery after esd.
|
| |
|
Additional Manufacturer Narrative
|
|
This report is being supplemented to provide additional information based on the legal manufacturer's final investigation.The device history record was unable to be reviewed for this device since the lot number was not provided.However, olympus only releases products to market that meet all manufacturing specifications and final product release criteria.Based on the results of the investigation, the relationship between the device and the adverse event cannot be confirmed.There was no complaint reported on the subject device.There is no evidence of an olympus device malfunction.Olympus will continue to monitor field performance for this device.
|
| |
|