Model Number DFW150
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Visual Disturbances (2140); Halo (2227); Discomfort (2330)
Date of Event 09/14/2021
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Patient weight and ethnicity: unknown/ not provided.The device is not received; therefore, a failure analysis of the complaint device cannot be completed.A review of the device/lot history record and complaint trending for this device will be performed.Upon completion of the review, if there is any further relevant information a supplemental medwatch will be filed.All pertinent information available to johnson & johnson surgical vision, inc.Has been submitted.
 
Event or Problem Description
It was reported that an intraocular lens (iol) was explanted from the patient's operative eye due to subjective poor visual quality, glare, halo, dysphotopsia, and the patient was very dissatisfied with outcome.Measured acuity was good: ranging from 20/20 to 20/30 and j1-j2 vision.Refractive error measured at -0.25+0.50 x 012.Retinal optical coherence tomography (oct) and corneal surface did not adequately explain patient symptoms.Patient felt that her vision was like looking through vaseline and after 2 months of failed adaptation, it was decided an exchange was the best course.There was no incision enlargement, no vitrectomy, no sutures done.Suspect iol was replaced with model zcb00 23.0 d (b)(4).There was no patient post-operative (op) injury.Patient is improving post-op, satisfied with vision after exchange so far.No other information was provided.
 
Additional Manufacturer Narrative
Section d9.Device available for evaluation? yes.Returned to manufacturer on: jan, 12, 2022.Section h3.Device evaluated manufacturer? yes.Device evaluation: visual inspection under magnification revealed viscoelastic residue on the haptics and optic body and that the lens was received cut in half.Based on the return condition of the lens, no further evaluation could be performed on the lens.The complaint issue could not be confirmed, and no product deficiency could be identified.All pertinent information available to johnson & johnson surgical vision, inc.Has been submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TECNIS SYNERGY TORIC II
Common Device Name
LENS, MULTIFOCAL INTRAOCULAR
Manufacturer (Section D)
AMO PUERTO RICO MFG. INC.
road 402 north, anasco ind. pk
anasco PR 00610
Manufacturer Contact
somyata nagpal
31 technology drive
irvine, CA 92618
7142478552
MDR Report Key13173227
Report Number3012236936-2022-00025
Device Sequence Number19962716
Product Code MFK
UDI-Device Identifier05050474751323
UDI-Public(01)05050474751323(17)240612
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
P980040
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Device Explanted Year2021
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 02/18/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date06/12/2024
Device Model NumberDFW150
Device Catalogue NumberDFW150U230
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/12/2022
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/15/2021
Supplement Date Received by Manufacturer02/18/2022
Initial Report FDA Received Date01/05/2022
Supplement Report FDA Received Date02/18/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured06/12/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age64 YR
Patient SexFemale
Patient RaceWhite
-
-