Model Number 234-010-179
Medical Device Problem Code Material Integrity Problem (2978)
Health Effect - Clinical Codes Device Embedded In Tissue or Plaque (3165); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/04/2021
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that the screw broke during the procedure and remained in the patient.
 
Additional Manufacturer Narrative
Additional information will be provided once the investigation has been completed.The device manufacturer date is not known at this time.However, should it become available it will be provided in future reports.This report was filed on behalf of the legal manufacturer - biocomposites.
 
Additional Manufacturer Narrative
The product was not returned for investigation therefore the reported failure mode was not confirmed.This investigation will be closed based on probable root cause.Alleged failure: screw broke.Customer complaint: "in the surgical act, when trying to insert the 11x35mm screw, it broke inside the patient." investigation findings are: screw broke during surgery, technique likely attributed to breakage.The suspected root causes are: improper technique, tap diameter insufficient leading to strain on the screw.The corrective action: no corrective action planned, surgery was completed successfully.The manufacture date is not known.The failure mode will be monitored for future reoccurrence.H3 other text: 81.
 
Event or Problem Description
It was reported that the screw broke during the procedure and remained in the patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PKG, 11MM X 35MM STRYKER BIOSTEON SCREW
Common Device Name
SCREW, FIXATION, BONE
Manufacturer (Section D)
STRYKER ENDOSCOPY-SAN JOSE
5900 optical court
san jose CA 95138
Manufacturer (Section G)
STRYKER ENDOSCOPY-SAN JOSE
5900 optical court
san jose CA 95138
Manufacturer Contact
andrea zenere
5900 optical court
san jose, CA 95138
4087542000
MDR Report Key13192575
Report Number0002936485-2022-00018
Device Sequence Number1580985
Product Code HWC
UDI-Device Identifier15060155710331
UDI-Public15060155710331
Combination Product (Y/N)N
Initial Reporter CountryBR
PMA/510(K) Number
K003641
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Distributor
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 02/15/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number234-010-179
Device Catalogue Number234-010-179
Device Lot NumberBS190608
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 12/10/2021
Supplement Date Received by Manufacturer12/10/2021
Initial Report FDA Received Date01/07/2022
Supplement Report FDA Received Date02/15/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexMale
-
-