| Catalog Number |
8065803650 |
| Medical Device Problem Codes |
Failure to Prime (1492); Suction Failure (4039)
|
| Health Effect - Clinical Codes |
Hemorrhage/Blood Loss/Bleeding (1888); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
|
| Date of Event |
12/03/2021
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
A nurse reported that an ophthalmic operating console presented no aspiration during a vitrectomy procedure.The vitrectomy probe was changed but the console did not prime.The console restarted and it did not prime again.The surgery was completed after replacing the console with another one.There was a slight delay in the procedure time.The patient experienced suprachoroidal hemorrhage as the result of the delay.The patient's symptoms are resolving.Additional information has been received clarifying that the scheduled procedure was "phaco cataract extraction and intraocular lens implant" surgery.The patient was transferred to neighbor facility and underwent vitreo-retinal procedure for the suprachoroidal hemorrhage.The patient is making a promising initial recovery.This is second of two reports for this reported event.
|
| |
|
Additional Manufacturer Narrative
|
|
Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.The manufacturer internal reference number is: (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
A sample was not received at the manufacturing site for evaluation for the report of there was no aspiration and the probe would not prime; therefore, the condition of the product could not be verified.No lot number was identified with this complaint; therefore, a device history record review could not be conducted.A sample was not received at the manufacturing site and no lot information is available, therefore, the root cause for the customer complaint issue cannot be determined.The cause of the reported event cannot be determined with the information obtained, therefore, specific action with regards to this complaint cannot be taken.Complaints are reviewed and monitored at regular intervals for any significant adverse trends.No adverse trends have been observed associated with the reported product and event.No additional action is required at this time.The manufacturer internal reference number is: (b)(4).
|
| |
|