Model Number APB-1-3-3D-ES
Medical Device Problem Code Physical Resistance/Sticking (4012)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/23/2021
Type of Reportable Event Malfunction
Event or Problem Description
Medtronic received a report that the axium coil could not be pushed out of the sheath before use.A replacement product was used to complete the procedure.It was indicated that all devices were prepared as per the instructions for use (ifu), and no patient symptoms or further complications were reported as a result of this event.The patient was undergoing surgery for treatment of a saccular, unruptured of the posterior communicating (pcom) artery aneurysm with a max diameter of 5.3 mm and a 3.7 mm neck diameter.It was noted the patient's blood flow and vessel tortuosity were normal.
 
Additional Manufacturer Narrative
The axium prime coil was returned for analysis.The axium prime pusher was found broken at the hypotube break indicator (hbi) with the release wire pulled.No bends or kinks were found with the remaining pusher.The introducer sheath was found stuck on the pusher.The introducer sheath was found inverted on the pusher with the wavelock portion at the distal end.The pusher release wire coin was found pulled back from the lumen stop and the implant coil was found detached from the pusher.The implant coil was not returned with the pusher.Based on the device analysis and reported information, the customer¿s ¿coil resistance/stuck in sheath¿ report could not be confirmed, and the cause could not be determined.It was reported the event occurred prior to use; however, as the pusher was found broken and the implant coil detached it appears the device was used.As the introducer sheath was found inverted it is likely that the customer inverted the axium prime coil following hydration, inspection, or after use.If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
Additional information was received indicating there was a problem with the coil before it was delivered into the microcatheter.The preparation process of the coil was normal operation.
 
Additional Manufacturer Narrative
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AXIUM PRIME BRPL 3D
Common Device Name
DEVICE, VASCULAR, FOR PROMOTING EMBOLIZATION
Manufacturer (Section D)
MICRO THERAPEUTICS, INC. DBA EV3
9775 toledo way
irvine CA 92618
Manufacturer (Section G)
MICRO THERAPEUTICS, INC. DBA EV3
9775 toledo way
irvine CA 92618
Manufacturer Contact
glen belmer
9775 toledo way
irvine, CA 92618
6122713209
MDR Report Key13214870
Report Number2029214-2022-00025
Device Sequence Number12190145
Product Code KRD
UDI-Device Identifier00847536031821
UDI-Public00847536031821
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K151447
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 01/19/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date10/23/2023
Device Model NumberAPB-1-3-3D-ES
Device Catalogue NumberAPB-1-3-3D-ES
Device Lot NumberB107226
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/23/2021
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/09/2022
Supplement Date Received by Manufacturer01/17/2022
Initial Report FDA Received Date01/10/2022
Supplement Report FDA Received Date01/19/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured10/23/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age65 YR
Patient SexMale
-
-