Model Number RFG-NT-1100
Medical Device Problem Code Failure to Power Up (1476)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/06/2022
Type of Reportable Event Malfunction
Event or Problem Description
During the procedure, with the patient on the table, the unit was not responding and the case was cancelled.The left side of the unit does not respond and the right side limited response.
 
Additional Manufacturer Narrative
One 3 lesion nt1100¿ pain management rf generator was received for analysis.Ac power was applied to the rf generator and the system successfully executed the power on self-test with no faults detected.During product testing the upper assembly control panel was not working.The unit was disassembled and it was observed to have physical damage to the power supply board; capacitor (c1) was sheared off from the psb.The psb was temporarily replaced with a known good one and the unit functioned as intended.User defined target temperatures were monitored and achieved on all ports.No faults, warnings or irregular heating periods were encountered during the evaluation performed.The device history record was reviewed to ensure that each manufacturing and inspection operation was performed.No non-conformances associated with the reported event were identified.Based on the information provided to abbott and the investigation performed, the root cause of the reported event was isolated to a sheared off capacitor on the power supply board.
 
Additional Manufacturer Narrative
The results of the investigation are inconclusive since the device was not returned for analysis.The device history record was reviewed to ensure that each manufacturing and inspection operation was performed.No non-conformances associated with the reported event were identified.Based on the information received, the cause of the reported startup issue and subsequent cancellation remain unknown.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
3 LESION NT1100¿ PAIN MANAGEMENT RF GENERATOR
Common Device Name
GENERATOR, LESION, RADIOFREQUENCY
Manufacturer (Section D)
ST. JUDE MEDICAL, INC.
one st. jude medical drive
st. paul MN 55117
Manufacturer (Section G)
ST. JUDE MEDICAL, INC.
one st. jude medical drive
st. paul MN 55117
Manufacturer Contact
janna parks
5050 nathan lane north
plymouth, MN 55442
6517565400
MDR Report Key13236688
Report Number2184149-2022-00006
Device Sequence Number4330469
Product Code GXD
UDI-Device Identifier05415067022370
UDI-Public05415067022370
Combination Product (Y/N)N
Initial Reporter StateNY
Initial Reporter CountryUS
PMA/510(K) Number
K052878
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 02/23/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Model NumberRFG-NT-1100
Device Catalogue NumberRFG-NT-1100
Device Lot Number7265744
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/08/2022
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/06/2022
Supplement Date Received by Manufacturer02/01/2022
02/15/2022
Initial Report FDA Received Date01/12/2022
Supplement Report FDA Received Date02/01/2022
02/23/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured04/04/2019
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Patient SexUnknown
-
-