• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: COOK IRELAND LTD EVOLUTION® ESOPHAGEAL CONTROLLED-RELEASE STENT - PARTIALLY COVERED; ESW PROSTHESIS, ESOPHAGEAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

COOK IRELAND LTD EVOLUTION® ESOPHAGEAL CONTROLLED-RELEASE STENT - PARTIALLY COVERED; ESW PROSTHESIS, ESOPHAGEAL Back to Search Results
Model Number G48032
Medical Device Problem Codes Insufficient Device Problem Information (3190); Activation Failure (3270)
Health Effect - Clinical Codes Insufficient Information (4580); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/15/2021
Type of Reportable Event Malfunction
Event or Problem Description
As per source doc: "customer indicated that they couldn't place the product".
 
Additional Manufacturer Narrative
Pma/510(k) # k162717.The investigation is in progress and a follow up mdr will be submitted.
 
Additional Manufacturer Narrative
Pma/510(k) # k162717 device evaluation the evo-20-25-12.5-e device of lot number c1875361 involved in this complaint was not available for evaluation.With the information provided, a document-based investigation was conducted.Several attempts were made to obtain additional information regarding this device.However, no response has been received to date.If it is returned in the future then the file will be updated accordingly.Document review including ifu review: prior to distribution evo-20-25-12.5-e devices are subjected to a visual inspection and functional checks to ensure device integrity.A review of the manufacturing records for evo-20-25-12.5-e of lot number c1875361 did not reveal any discrepancies that could have contributed to this complaint issue.The review of relevant manufacturing records, confirms the failure mode has not previously occurred with the current lot number.Based on the information available to date, there is no evidence to suggest that there are any manufacturing issues associated with lot number c1875361.It should be noted that the instructions for use (ifu0061) states the following: "visually inspect with particular attention to kinks, bends and breaks.If abnormality is detected that would prohibit proper working condition, do not use." there is not sufficient evidence to suggest the user did not follow the ifu.Root cause review a definitive root cause could not be determined from the available information.Due to the limited information available it was agreed with engineering that assigning the most common inability to deploy failure mode section would be the most appropriate approach in this case.Typically the most common possible root cause attributed to inability to deploy has been tortuous patient anatomy.It is possible that during deployment tortuous path may have caused a build-up of pressure and resulting in deployment difficulties.However, as the device was not returned for evaluation; the cause of this complaint could not be conclusively determined.Summary the complaint is confirmed based on customer testimony.It is unknown whether the patient experienced any adverse effects due to this occurrence.Complaints of this nature will continue to be monitored for potential emerging trends.
 
Event or Problem Description
Supplemental report is being submitted due to the completion of the investigation.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EVOLUTION® ESOPHAGEAL CONTROLLED-RELEASE STENT - PARTIALLY COVERED
Common Device Name
ESW PROSTHESIS, ESOPHAGEAL
Manufacturer (Section D)
COOK IRELAND LTD
o halloran road
limerick
Manufacturer (Section G)
COOK IRELAND LTD
o halloran road
national technology park
limerick
Manufacturer Contact
sinead o'leary
o halloran road
national technology park
limerick 
MDR Report Key13246693
Report Number3001845648-2022-00012
Device Sequence Number4119041
Product Code ESW
UDI-Device Identifier10827002480329
UDI-Public(01)10827002480329(17)231007(10)C1875361
Combination Product (Y/N)N
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 06/10/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date10/07/2023
Device Model NumberG48032
Device Catalogue NumberEVO-20-25-12.5-E
Device Lot NumberC1875361
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Distributor Facility Aware Date12/15/2021
Event Location Hospital
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 12/16/2021
Supplement Date Received by Manufacturer12/16/2021
Initial Report FDA Received Date01/13/2022
Supplement Report FDA Received Date07/07/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured10/07/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-