MAUDE Adverse Event Report: ALCON RESEARCH, LLC - HUNTINGTON ACRYSOF IQ ASPHERIC UV ABSORBING IOLWITH ULTRASERT DELIVERY SYSTEM; INTRAOCULAR LENS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ALCON RESEARCH, LLC - HUNTINGTON ACRYSOF IQ ASPHERIC UV ABSORBING IOLWITH ULTRASERT DELIVERY SYSTEM; INTRAOCULAR LENS Back to Search Results
Model Number ACU0T0
Medical Device Problem Codes Device Damaged by Another Device (2915); Scratched Material (3020)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/24/2021
Type of Reportable Event Malfunction
Event or Problem Description
A nurse reported that during an intraocular lens (iol) implant procedure, iol trailing haptic was broken at the joint after insertion in to the eye and causing the causing scratches and marks on the optic and there was no chance of the lens being able to sit comfortably in the eye without causing further complications.This problem causing delayed surgery time and prolonged anesthetic as the patient was under general anesthetic.Additional information received and stated that, the haptic was broken where it meets the optic and the optic itself was affected.There was no harm caused to the patient as the surgeon was able to cut the lenses inside the eye and replace with a third iol.The only real issue it caused the patient was a prolonged hospital stay due to needing a longer general anesthetic.All issues have been resolved and the patient has good vision following surgery.The patient was not hospitalized and went home the same day.The temperature and humidity levels in theatre were also optimum and caused no problems that may have influenced this event.
 
Additional Manufacturer Narrative
A sample device was not returned for analysis.Complaint history and product history records were reviewed and documentation indicated the product met release criteria.Root cause has not been identified.There have been no other complaints reported in the lot number.The manufacturer internal reference number is: (b)(4).
 
Additional Manufacturer Narrative
Only a photo was attached to the file.The photo also appears in the other (b)(4).The file indicated the event occurred two times with two separate lenses and a final third lens was implanted successfully.The photo showed the tip of the company device inside the incision.The leading haptic and the optic appeared to have been completely inserted into the eye.A scratch cannot be confirmed based on this photo.The trailing haptic appeared to be torn at the haptic/optic junction with a portion of the trailing haptic caught inside the device tip.The distal area of the trailing haptic extended outside the device tip and was located inside the eye above or on the anterior surface of the optic.Viscoelastic was not provided.It is unknown if a qualified product was used.The product investigation could not identify a root cause for the reported complaint.The reported scratch could not be confirmed.The available photo shows the trailing haptic caught in the device tip and torn at the optic junction.The plunger position in relation to the broken haptic during advancement cannot be determined.The ifu (instructions for use) instructs: after the lens has been advanced to the nozzle line, the lens should be visually inspected to determine the position of the haptics.The plunger should be in contact with the trailing optic edge.After confirming the lens is properly positioned and the haptics are folded properly, proceed with lens implantation.Proceeding with implantation of a misfolded haptic or a lens that appears to be ¿out of position¿ can result in a broken haptic or other negative outcome, since the haptic may be trapped and stretched, and/or pinched and sheared by the moving plunger.It is unknown if a qualified viscoelastic was used.The ifu instructs: during device preparation and implantation of the company iol (intraocular lens) with the company preloaded delivery system, an company qualified ophthalmic viscoelastic device (ovd) should be used.The use of an unqualified ovd may cause damage to the lens and potential complications during the device preparation and implantation steps.Broken haptics may occur: due to the use of a non-qualified viscoelastic.Material properties of non-qualified ovds may contribute to underfill, overfill, misfolding of the haptics, or other inconsistent folding outcomes.If the operating room temperature is too high (> 23°c / 73° f) lens folding consistency is negatively affected, the lens is more adherent and this may inhibit lens advancement.In addition, haptic strength (modulus) decreases as the temperature increases and is more likely to break under stress.If the device is overfilled with ovd as this can prevent the trailing haptic from being placed properly or move the lens out of position resulting in misfolding.If a straight trailing haptic occurs and it was not properly detected to be out of position.If the plunger is not fully advanced, or if the plunger is allowed to retract, the trailing haptic may not release properly from the device.Any of the above listed causes alone, or in combination, may create the reported event.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ACRYSOF IQ ASPHERIC UV ABSORBING IOLWITH ULTRASERT DELIVERY SYSTEM
Common Device Name
INTRAOCULAR LENS
Manufacturer (Section D)
ALCON RESEARCH, LLC - HUNTINGTON
6065 kyle lane
huntington WV 25702
Manufacturer (Section G)
ALCON RESEARCH, LLC - HUNTINGTON
6065 kyle lane
huntington WV 25702
Manufacturer Contact
jonathan schlech
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
8007579780
MDR Report Key13252721
Report Number1119421-2022-00090
Device Sequence Number4431888
Product Code HQL
UDI-Device Identifier00380652395328
UDI-Public00380652395328
Combination Product (Y/N)N
Initial Reporter CountryUK
PMA/510(K) Number
P930014
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility
Initial Reporter Occupation Nurse
Type of Report Initial,Followup
Report Date (Section B) 03/15/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/01/2024
Device Model NumberACU0T0
Device Lot Number15244039
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 12/28/2021
Supplement Date Received by Manufacturer02/21/2022
Initial Report FDA Received Date01/13/2022
Supplement Report FDA Received Date03/15/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured08/03/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age82 YR
Patient SexMale
-
-