Model Number 7753500
Medical Device Problem Codes Break (1069); Material Deformation (2976)
Health Effect - Clinical Code Device Embedded In Tissue or Plaque (3165)
Date of Event 12/22/2021
Type of Reportable Event Malfunction
Event or Problem Description
Information was received from healthcare professional via field representative regarding patient with pre-op diagnosis- myelopathy involved in the posterior cervical fusion procedure.It was reported that during procedure, while torquing the mas locking screw, it breaks the bottom mas connector.They could not remove this broken setscrew once it¿s broken.The bottom of the mas connectors x4 are still in the patient body as they have been stripped during insertion of crosslinks x2.Product was utilized correctly according to the directions given in the ifu/labeling.There were no patient symptoms or complications reported as a result of this event.On 2022-jan-18, received additional information that lot numbers for the reported products are not available.There was a delay in surgery, it would have been about 15 minutes.None of the actual crosslinks broke, it was the setscrew that breaks when it is final torqued.No revision surgery scheduled.
 
Additional Manufacturer Narrative
Neither the device nor films of applicable imaging studies were returned to the manufacturer for evaluation.Therefore, we are unable to determine the definitive cause of the reported event.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VERTEX RECONSTRUCTION SYSTEM
Common Device Name
APPLIANCE, FIXATION, SPINAL INTERLAMINAL
Manufacturer (Section D)
WARSAW ORTHOPEDICS
2500 silveus crossing
warsaw IN 46582
Manufacturer (Section G)
WARSAW ORTHOPEDICS
2500 silveus crossing
warsaw IN 46582
Manufacturer Contact
glen belmer
1800 pyramid place
memphis, TN 38132
6122713209
MDR Report Key13288029
Report Number1030489-2022-00052
Device Sequence Number17213607
Product Code KWP
UDI-Device Identifier00613994448743
UDI-Public00613994448743
Combination Product (Y/N)N
Initial Reporter CountryAS
PMA/510(K) Number
K082728
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2021
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 01/19/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number7753500
Device Catalogue Number7753500
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/22/2021
Initial Report FDA Received Date01/19/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-