• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BECTON DICKINSON MEDICAL (SINGAPORE) BD LUER-LOK¿ SYRINGE WITH DETACHABLE BD ECLIPSE¿ NEEDLE; HYPODERMIC SINGLE LUMEN NEEDLE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BECTON DICKINSON MEDICAL (SINGAPORE) BD LUER-LOK¿ SYRINGE WITH DETACHABLE BD ECLIPSE¿ NEEDLE; HYPODERMIC SINGLE LUMEN NEEDLE Back to Search Results
Model Number 305782
Medical Device Problem Code Volume Accuracy Problem (1675)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/24/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Multiple lot numbers: there were multiple lot numbers reported to be involved.The information for each lot number is as follows: medical device lot #: 1147619 medical device expiration date: 05/31/2026 device manufacture date: 05/27/2021 medical device lot #: 1084899.Medical device expiration date: 03/31/2026.Device manufacture date: 03/25/2021.Medical device lot #: 1204165.Medical device expiration date: 07/31/2026.Device manufacture date: 07/23/2021.Medical device lot #: 0300498.Medical device expiration date: 10/31/2025.Device manufacture date: 10/26/2020.There were multiple pma / 510(k)#s reported to be involved.The information for each 510(k) number is as follows: pma / 510(k)#: k980987 (syringe).Pma / 510(k)#: k161170 (needle).A device evaluation is anticipated but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event or Problem Description
It was reported that there were scale marking issues on the bd luer-lok¿ syringe with detachable bd eclipse¿ needle.This event occurred 56 times.There was no report of patient impact.The following information was provided by the initial reporter: "syringe scale is skewed.".
 
Additional Manufacturer Narrative
Multiple lot numbers: there were multiple lot numbers reported to be involved.The information for each lot number is as follows: medical device lot #: 1147619 medical device expiration date: 05/31/2026 device manufacture date: 05/27/2021 medical device lot #: 1084899.Medical device expiration date: 03/31/2026.Device manufacture date: 03/25/2021.Medical device lot #: 1204165.Medical device expiration date: 07/31/2026.Device manufacture date: 07/23/2021.Medical device lot #: 0300498.Medical device expiration date: 10/31/2025.Device manufacture date: 10/26/2020.There were multiple pma / 510(k)#s reported to be involved.The information for each 510(k) number is as follows: pma / 510(k)#: k980987 (syringe).Pma / 510(k)#: k161170 (needle).A device evaluation is anticipated but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event or Problem Description
It was reported that there were scale marking issues on the bd luer-lok¿ syringe with detachable bd eclipse¿ needle.This event occurred 56 times.There was no report of patient impact.The following information was provided by the initial reporter: "syringe scale is skewed.".
 
Additional Manufacturer Narrative
The following fields were updated due to additional information: d.9.Device available for eval?: yes.D.9.Returned to manufacturer on: 1/14/2022.H.6.Investigation: fifty-six (56) samples were received by our quality team for evaluation.One sample in sealed packaging was received for batch 0300498, three samples in sealed packaging for 1084899, two samples in sealed packaging for 1204165, and forty-seven (47) in sealed packaging and three samples with open packaging for batch 1147619.All samples were subjected to visual inspection.Eleven of the returned samples were observed with slight skewed scale marking, one sample from batch 0300498, three samples from batch 1084899, two samples from batch 1204165, and five samples from batch 1147619.All eleven samples identified with skewed scale marking were subjected to volumetric testing and passed.A review of the internal manufacturing device records and raw material history files for the reported lot numbers was performed and no recorded quality problems or rejections to this incident were found.Although there is a slight skew in the scale marking, it does not affect the dosage of the solution as the volumetric test is within specification.An investigation was conducted at the syringe apex printing machine to find the cause of the skewed printing.The printing pad set up plays an important role to achieve good printing on the barrel.With a good printing pad set up, consistent printing is achieved as the printing pad is secured on the printing drum.It was understood that any slight skewed printing was deemed acceptable during routine inspection as this defect does not affect the volumetric test.Therefore, the root cause is attributed to the inattentiveness of the slight skewed printing defect by the production technician during printing pad set-up and by both the manufacturing and quality assurance associate during routine inspection.
 
Event or Problem Description
It was reported that there were scale marking issues on the bd luer-lok¿ syringe with detachable bd eclipse¿ needle.This event occurred 56 times.There was no report of patient impact.The following information was provided by the initial reporter: "syringe scale is skewed.".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD LUER-LOK¿ SYRINGE WITH DETACHABLE BD ECLIPSE¿ NEEDLE
Common Device Name
HYPODERMIC SINGLE LUMEN NEEDLE
Manufacturer (Section D)
BECTON DICKINSON MEDICAL (SINGAPORE)
30 tuas avenue 2
singapore
Manufacturer (Section G)
BECTON DICKINSON MEDICAL (SINGAPORE)
30 tuas avenue 2
singapore
Manufacturer Contact
phillip emmert
9450 south state street
sandy, UT 84070
8015296192
MDR Report Key13290932
Report Number8041187-2022-00015
Device Sequence Number17245483
Product Code FMI
UDI-Device Identifier30382903057826
UDI-Public30382903057826
Combination Product (Y/N)N
Initial Reporter CountryTW
PMA/510(K) Number
SEE H.10.
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 02/25/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number305782
Device Catalogue Number305782
Device Lot NumberSEE H.10.
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/24/2021
Supplement Date Received by Manufacturer02/25/2022
Initial Report FDA Received Date01/19/2022
Supplement Report FDA Received Date03/12/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-