• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: C.R. BARD, INC. (BASD) -3006260740 HUBER PLUS 20G X 1" NEEDLELESS Y SITE; SET, ADMINISTRATION, INTRAVASCULAR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

C.R. BARD, INC. (BASD) -3006260740 HUBER PLUS 20G X 1" NEEDLELESS Y SITE; SET, ADMINISTRATION, INTRAVASCULAR Back to Search Results
Model Number N/A
Medical Device Problem Codes Fluid/Blood Leak (1250); Material Deformation (2976)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/30/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The manufacturer has received the sample and will evaluate.Results are expected soon.A lot history review (lhr) of refs1473 showed five other similar product complaint(s) from this lot number.
 
Event or Problem Description
It was reported that cancer patient bought huber plus from pharmacy in this hospital and brought to facility.Staff nurse inserted needle to chemoport and connected luer lock syringe contained 10ml of normal saline to main hub, normal saline leaked and spilled from y-site, once she infused.She stopped the procedure and informed medical officer in-charged.Cancer patient is fine.
 
Event or Problem Description
It was reported that cancer patient bought huber plus from pharmacy in this hospital and brought to facility.Staff nurse inserted needle to chemoport and connected luer lock syringe contained 10ml of normal saline to main hub, normal saline leaked and spilled from y-site, once she infused.She stopped the procedure and informed medical officer in-charged.Cancer patient is fine.
 
Additional Manufacturer Narrative
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The following were reviewed as part of this investigation: patient severity, trend analysis, applicable previous investigation(s), sample (if available), and applicable fmea documents.Based on a review of this information, the following was concluded: the complaint of a leaking infusion set was confirmed; however, the root cause was not identified.The product returned for evaluation was one 20ga x 1¿ huber plus safety infusion set with valved y-site.Usage residues were observed throughout the sample and the safety mechanism was not engaged.The y-site valve orifice appeared elliptical.Microscopic inspection of the y-site confirmed the orifice to be elliptical.Inspection of the y-site orifice using an iso taper gauge revealed the y-site to be outside of manufacturing specifications.The shape of the luer prevented full insertion of the taper gauge.An attempt to infuse water through the sample using a 12m syringe revealed the sample to be patent to infusion; however, a spraying leak was observed emanating from the y-site valve septum.The misshapen valve housing appeared to be the cause of the valve septum leakage.The lack of evidence of attempted use and the lack of mechanical damage suggested the valve housing deformation did not occur during device use; however, it could not be determined if the deformation occurred during the manufacturing process or due to subsequent environmental conditions.Potential contributing factors include exposure to excessive heat during shipping/storage.H3 other text : evaluation findings are in section h.11.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HUBER PLUS 20G X 1" NEEDLELESS Y SITE
Common Device Name
SET, ADMINISTRATION, INTRAVASCULAR
Manufacturer (Section D)
C.R. BARD, INC. (BASD) -3006260740
605 north 5600 west
salt lake city 84116
Manufacturer (Section G)
BARD REYNOSA S.A. DE C.V. -9617592
blvd. montebello #1
parque industrial colonial
reynosa, tamaulipas 88780
MX   88780
Manufacturer Contact
johanna de oliveira
605 north 5600 west
salt lake city 84116
8015950700
MDR Report Key13310921
Report Number3006260740-2021-05676
Device Sequence Number3672907
Product Code FPA
UDI-Device Identifier00801741065569
UDI-Public(01)00801741065569
Combination Product (Y/N)N
Initial Reporter CountryMY
PMA/510(K) Number
K993848
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other,Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 03/24/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberN/A
Device Catalogue Number012001NY
Device Lot NumberREFS1473
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/18/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 12/30/2021
Supplement Date Received by Manufacturer03/24/2022
Initial Report FDA Received Date01/20/2022
Supplement Report FDA Received Date03/25/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/01/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-