The manufacturer was contacted in reference to the voluntary field safety notice / recall notification related to the sound abatement foam in certain cpap, bipap, and mechanical ventilator devices.The manufacturer previously received information allegation issue related to a cpap device's sound abatement foam.Patient alleged to develop a bladder tumor.The patient required surgery in response to the reported event.There was no report of patient harm or injury.Repeated attempts to have the device and components returned for evaluation and investigation were unsuccessful.The manufacturer believes they will be unable to gather additional information.The manufacturer is submitting a final report at this time.If pertinent information becomes available to the manufacturer at a later date, an addendum to this final report will be filed.Section h6 updated in this report.Section h6 codes has been updated as a correction for previous report.
|
|
Additional information was received on sep 06, 2024, and section h11 should be reported as: the manufacturer was contacted in reference to the voluntary field safety notice / recall notification related to the sound abatement foam in certain cpap, bipap, and mechanical ventilator devices.The manufacturer previously received information allegation issue related to a cpap device's sound abatement foam.Patient alleged to develop a bladder tumour, hard of breathing, raspiness in lungs and respiratory issues.The patient required surgery in response to the reported bladder tumour.The device was returned to the manufacturer's product investigation laboratory for investigation.During the external and internal inspection, the manufacturer observed ui (users interface) knob missing.The air outlet port had dust-like contamination in it.Air inlet had white dust-like contamination in it.Pca (printed circuit assembly) had light dust-like contamination all over the top of it.Dust-like contamination on the top of the blower box lid and surrounding area and also on the top of the blower motor and inside of the blower box and bottom enclosure.Air inlet seal had yellowed and had dust-like contamination on it.The sound abatement foam was intact and had dust-like contamination on top of it.Evidence of sound abatement foam degradation/breakdown was not observed in this device.During internal and external inspection of humidifier, the manufacturer observed dust-like contamination on flip lid seal, water chamber missing.Tan and white dust-like contamination, throughout humidifier enclosure.Unknown tan dust-like contamination on and under the heater plate.Unknown white dust-like contamination on the dry box seals.Unknown white and brown dust-like contamination in the iso port (international organization of standardization).The contamination found in the humidifier enclosure are considered not to be in the airpath.The manufacturer was not able to confirm the presence of degraded sound abatement foam.The device's event logs were downloaded and reviewed by manufacturer.The manufacturer found no error codes.The manufacturer applied power to the device and verified airflow.The manufacturer concludes that there was no evidence of sound abatement foam degradation.The manufacturer confirmed the source of contamination was external to the device.The manufacturer was missed to capture respiratory issues in previous report, which was corrected in this report.
|