• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: INTUITIVE SURGICAL, INC DA VINCI; HARMONIC ACE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

INTUITIVE SURGICAL, INC DA VINCI; HARMONIC ACE Back to Search Results
Model Number 480275-08
Device Problem Thermal Decomposition of Device (1071)
Patient Problems Foreign Body In Patient (2687); Insufficient Information (4580)
Event Date 12/21/2021
Event Type  Injury  
Manufacturer Narrative
Intuitive surgical, inc.(isi) received the harmonic ace instrument involved with this complaint and completed the device evaluation.Failure analysis (fa) investigations replicated and confirmed the customer reported complaint "teflon pad was melting and fragments were falling down".Failure analysis found the primary failure of teflon pad damage to be related to the customer complaint.Visual inspection of the instrument found the teflon pad exhibited thermal damage near the base of the clamp arm.A piece measuring roughly 0.027" x 0.034" was missing from the teflon pad and was not returned with the instrument.No blade damage was observed.The root cause for the teflon pad damage is attributed to mishandling/misuse.A review of the instrument log for the harmonic ace (part # 480275-08/lot# l902109220086) associated with this event has been performed.Per logs, the instrument was last used on (b)(6) 2021, on system sk3594.This is a single-use instrument.In addition, a review of the site's complaint history identified no other complaints related to the instrument and or this event.No image or video clip for the reported event was submitted to isi for review.Based on the information provided at this time, this complaint is being classified as a reportable adverse event due to the following conclusion: the harmonic ace instrument was found to have the teflon pad melted.The fragments fell inside the patient and were not retrieved.Failure analysis confirmed the issue and the root cause was attributed to user mishandling or misuse.Per fa investigation findings, there is no evidence that a device malfunction caused/contributed to the alleged event.
 
Event Description
It was reported that during a da vinci-assisted thyroidectomy surgical procedure, the harmonic ace instrument was found to have the teflon pad melted, and fragments were falling inside the patient.The fragments were not retrieved.The customer removed the instrument and used a backup instrument to complete the procedure.Intuitive surgical, inc.(isi) followed up with the initial reporter and obtained the following additional information: the instrument was inspected prior to use with no damage observed.The teflon pad melted like powder as soon as the customer started to use the instrument.The fragments were not retrieved as they were noted to be "like powder." it was unknown what caused the melting to occur as the instrument did not collide with any hard materials or other instruments, and the customer confirmed that arcing was not observed.The thyroid tissue did not appear to be too thick.The surgeon did not notice any issues with the functionality of the instrument.No post-operative tests like an x-ray or ultrasound were performed, and no additional surgical procedure was performed.The patient has not returned to the hospital due to experiencing any post-surgical complications related to retaining a foreign object.The da vinci 8 mm harmonic ace curved shears is a single-use, sterile instrument used to deliver ultrasonic energy to enable transection and coagulation of tissue.It is designed to be used in conjunction with a compatible da vinci surgical system and a compatible ethicon endo-surgery generator and hand piece.
 
Manufacturer Narrative
Based on a re-evaluation of the complaint information, this complaint has been reclassified as an adverse event and product problem rather than just a adverse event, as previously reported.Corrected information can be found the following field: b1, h6 b1 updated from "adverse event" to "adverse event and product problem".
 
Event Description
Refer to h10/h11 for follow-up information.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DA VINCI
Type of Device
HARMONIC ACE
Manufacturer (Section D)
INTUITIVE SURGICAL, INC
3410 central expressway
santa clara CA
Manufacturer (Section G)
INTUITIVE SURGICAL, INC
3410 central expressway
santa clara CA
Manufacturer Contact
izabel nielson
3410 central expressway
santa clara, CA 
4085232100
MDR Report Key13314710
MDR Text Key284182348
Report Number2955842-2022-10106
Device Sequence Number1
Product Code NAY
UDI-Device Identifier10886874112738
UDI-Public(01)10886874112738(17)230930(10)L90210922
Combination Product (y/n)N
Reporter Country CodeKS
PMA/PMN Number
K143132
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Foreign,Health Professional
Reporter Occupation Nurse
Remedial Action Other
Type of Report Initial,Followup
Report Date 12/23/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number480275-08
Device Catalogue Number480275
Device Lot NumberL90210922 0086
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/11/2022
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 12/23/2021
Initial Date FDA Received01/21/2022
Supplement Dates Manufacturer Received12/23/2021
Supplement Dates FDA Received05/24/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured09/21/2021
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Removal/Correction NumberN/A
Patient Sequence Number1
Treatment
DA VINCI INSTRUMENTS AND ACCESSORIES
-
-