MAUDE Adverse Event Report: CLARE DISCRETE MFG IO ACCESS SARS-COV-2 IGG; IN VITRO DIAGNOSTIC DEVICES: CORONAVIRUS SEROLOGICAL REAGENTS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

CLARE DISCRETE MFG IO ACCESS SARS-COV-2 IGG; IN VITRO DIAGNOSTIC DEVICES: CORONAVIRUS SEROLOGICAL REAGENTS Back to Search Results
Catalog Number C58961
Medical Device Problem Code False Negative Result (1225)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/29/2021
Type of Reportable Event Malfunction
Event or Problem Description
On (b)(6) 20211 the customer reported repeatable non-reactive sars-cov-2 igg (access sars-cov-2 igg assay, part number c58961, lot number 172108) and sars-cov-2 igg ii (access sars-cov-2 igg ii assay, part number c69057, lot number not provided) results were generated for one patient on the customer's unicel dxi 800 access immunoassay analyzer (part number 973100 and serial number 606202).The customer reported reactive results using vitros 5600 cov2g assay.This report address the repeatable non-reactive sars-cov-2 igg results.A second report will address the non-reactive access sars-cov-2 igg ii results.On (b)(6) 2021, the access sars-cov-2 igg results were 0.66 s/co (non-reactive: <1.0 s/co), repeated at 0.75 s/co the day after.The access sars-cov-2 igg ii result was also non-reactive at 6.47 au/ml (non reactive: < 10 au/ml) on (b)(6) 2021.A second sample from the same patient gave similar results.On (b)(6) 2021 the access sars-cov-2 igg results were 0.67 s/co, repeated at 0.66 s/co the day after.The access sars-cov-2 igg ii result was also non-reactive at 6.44 au/ml on (b)(6) 2021.On 30dec2021, both samples were tested using vitros 5600 cov2g assay with discordant reactive results (sample one: 14.0 and sample two: 14.6).No affect to patients or end-users has been reported in connection with this event.The customer did not provide information on patient symptoms, vaccination, or pcr (polymerase chain reaction) or covid antigen test results.No further information was provided.No hardware errors or issues with other assays were reported in conjunction with this event.A passing system check was obtained on 21dec2021.A passing calibration curve was obtained on 23dec2021 using reagent lot 172108 and calibrator lot 125386 for sars-cov-2 igg.Quality control (qc) was passing within the laboratory¿s established ranges.There were no issues with sample integrity reported by the customer.Sample collection, handling and processing information such as sample type, sample volume collected, centrifugation, storage and other sample related information was not provided by the customer.
 
Additional Manufacturer Narrative
The fill patient identifier is (b)(6).The access sars-cov-2 igg reagent was not returned for evaluation.No hardware errors or other assay issues were reported in conjunction with this event.¿sars-cov-2 is an enveloped non-segmented positive-sense rna virus.It has several structural proteins including spike (s), envelope (e), membrane (m) and nucleocapsid (n).The spike protein (s) contains a receptor binding domain (rbd) which is responsible for recognizing the cell surface receptor, angiotensin converting enzyme-2 (ace2).It is found that the rbd of the sars-cov-2 s protein strongly interacts with the human ace2 receptor leading to endocytosis into the host cells and viral replication.The access assay detect antibodies directed against the spike protein, which are more likely to neutralize the virus.No manufacturer guarantees both a specificity and sensitivity of 100%.The concentration of sars-cov-2 igg in a given specimen determined with assays from different manufacturers can vary due to differences in assay methods, diversity of antibodies and reagent specificity.Differences in each individual assay are expected.In conclusion the cause of the discordant results could not be determined with the available information.Values obtained with different assay methods should not be used interchangeably and difference between methods are expected.There is no evidence to reasonably suggest that a malfunction occurred in conjunction with this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ACCESS SARS-COV-2 IGG
Common Device Name
IN VITRO DIAGNOSTIC DEVICES: CORONAVIRUS SEROLOGICAL REAGENTS
Manufacturer (Section D)
CLARE DISCRETE MFG IO
lismeehan
o'callaghans mills
EI 
Manufacturer (Section G)
CLARE DISCRETE MFG IO
lismeehan
o'callaghans mills
EI  
Manufacturer Contact
angela vettel
250 s. kraemer blvd.
brea, CA 92821
7149613625
MDR Report Key13343032
Report Number9680746-2022-00001
Device Sequence Number14481016
Product Code QKO
UDI-Device Identifier15099590738648
UDI-Public(01)15099590738648(17)220213(11)210618(10)172108
Combination Product (Y/N)N
Initial Reporter CountryIN
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 01/25/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date02/13/2022
Device Catalogue NumberC58961
Device Lot Number172108
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Distributor Facility Aware Date12/29/2021
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/29/2021
Initial Report FDA Received Date01/25/2022
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured06/18/2021
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Patient SexUnknown
-
-