Model Number CNA0T0
Medical Device Problem Code Inaccurate Delivery (2339)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/28/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The product was returned for analysis.Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.There was two other complaints reported in the lot number.The manufacturer internal reference number is: (b)(4).
 
Event or Problem Description
A pharmacist reported that during a cataract extraction with intraocular lens (iol) implant procedure, the intraocular lens (iol) came out of the patient¿s eye at the time of the injection.The incident occurred during the implant introduction into the patient's eye.The device touched the patient's eye.Another implant was used.There were no clinical consequences observed for the patient.Additional information has been requested.
 
Additional Manufacturer Narrative
The product was returned for analysis and the reported complaint could not be confirmed.The device was returned in the blister tray in the carton.The lock-out assembly has been removed.The plunger is oriented correctly.The correct nozzle confirmed on the device.Viscoelastic is observed in the device.The plunger has been advanced at the wound guard.A few iol (intraocular lens) segments are observed around the plunger tip.No iol returned.The product investigation could not identify the root cause for the reported complaint "the implant came out of the eye at the time of the injection".The plunger was observed to be advanced at the wound guard, a few iol segments are observed around the plunger tip.If the plunger is not fully advanced, the iol may not release properly from the device.Based on the results from the product history record, the products met release criteria.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CLAREON IOL WITH THE AUTONOME DELIVERY SYSTEM
Common Device Name
INTRAOCULAR LENS
Manufacturer (Section D)
ALCON LABORATORIES IRELAND LTD.
cork business&technology park
model farm road
cork 00000
EI  00000
Manufacturer (Section G)
ALCON LABORATORIES IRELAND LTD.
cork business&technology park
model farm road
cork 00000
EI   00000
Manufacturer Contact
jonathan schlech
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
8007579780
MDR Report Key13363778
Report Number9612169-2022-00024
Device Sequence Number20129897
Product Code HQL
UDI-Device Identifier00380652396479
UDI-Public00380652396479
Combination Product (Y/N)N
Initial Reporter CountryFR
PMA/510(K) Number
P190018
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Pharmacist
Type of Report Initial,Followup
Report Date (Section B) 04/01/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date03/31/2022
Device Model NumberCNA0T0
Device Lot Number21269869
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/24/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/06/2022
Supplement Date Received by Manufacturer03/11/2022
Initial Report FDA Received Date01/27/2022
Supplement Report FDA Received Date04/01/2022
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured04/09/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
DUOVISC VISCOELASTIC SYSTEM
Patient SexUnknown
-
-