Model Number 29420
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/05/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(6).
 
Event or Problem Description
It was reported that the catheter broke.A 135/10 renegade hi flo was selected for use.During the preparation, it was noted that the catheter broke as it was taken out from the hoop after flushing.The procedure was completed with a different device.There were no complications reported.
 
Additional Manufacturer Narrative
E1.Initial reporter facility name: (b)(6) medical center.Device evaluated by manufacturer: the device was returned for analysis.The device was inspected for any damage or irregularities.The device showed damage in the form of stretching and a fracture located 5.5cm from the hub.The device was not completely separated, the inner liner was still attached.Analysis showed kinks on the catheter shaft located 150cm to 151cm from the hub.Inspection of the remainder of the device, apart from the observed damage, revealed no other damage or irregularities.
 
Event or Problem Description
It was reported that the catheter broke.A 135/10 renegade hi flo was selected for use.During the preparation, it was noted that the catheter broke as it was taken out from the hoop after flushing.The procedure was completed with a different device.There were no complications reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RENEGADE HI-FLO
Common Device Name
CATHETER, CONTINUOUS FLUSH
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer (Section G)
BOSTON SCIENTIFIC CORK LIMITED
model farm road
cork
EI  
Manufacturer Contact
jay johnson
two scimed place
maple grove, MN 55311
7634942574
MDR Report Key13367447
Report Number2134265-2022-00616
Device Sequence Number14790738
Product Code KRA
UDI-Device Identifier08714729280637
UDI-Public08714729280637
Combination Product (Y/N)N
Initial Reporter StateIL
Initial Reporter CountryUS
PMA/510(K) Number
K140329
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 02/18/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date04/23/2024
Device Model Number29420
Device Catalogue Number29420
Device Lot Number0027374319
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/24/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 01/07/2022
Supplement Date Received by Manufacturer01/28/2022
Initial Report FDA Received Date01/27/2022
Supplement Report FDA Received Date02/18/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/24/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-