• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: LEICA BIOSYSTEMS NEWCASTLE LTD BOND¿ READY-TO-USE PRIMARY ANTIBODY C-ERBB-2 ONCOPROTEIN; BOND¿ READY-TO-USE PRIMARY ANTIBODY C-ERBB-2 ONCOPROTEIN - PA0571

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

LEICA BIOSYSTEMS NEWCASTLE LTD BOND¿ READY-TO-USE PRIMARY ANTIBODY C-ERBB-2 ONCOPROTEIN; BOND¿ READY-TO-USE PRIMARY ANTIBODY C-ERBB-2 ONCOPROTEIN - PA0571 Back to Search Results
Model Number PA0571
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 11/24/2021
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Manufacturer evaluation of the information available, which includes the relevant run events and service events, indicates that the two (2) slides for which false positive staining was reported (hereafter referred to as the "affected slides") were: - slide id 299e with case id (b)(6) which was stained at slide position 5 on slide staining assembly (ssa) 1 in run 20651 executed on (b)(6) 2021, and - slide id 2bq8 with case id (b)(6) , which was stained at slide position 3 on ssa 1 in run 21164 executed on 24 november 2021.Staining of both affected slides was performed using bond-iii automated stainer serial number (b)(6) completed successfully with no recorded event(s) to suggest any malfunction(s) of the instrument.Additionally, slide id 299e was stained in run 20651 together with two (2) other slides with bond slide ids 2994 and 2997 using the same staining protocol and the same reagents with no problem regarding the quality of staining reported to the manufacturer for slides with slide ids 2994 and 2997; and slide id 2bq8 was stained in run 21164 together with three (3) other slides with bond slide ids 2bqb, 2bp8 and 2bpq using the same staining protocol and the same reagents, with no problem regarding the quality of staining reported to the manufacturer for slides with slide ids 2bqb, 2bp8 and 2bpq.The information available also indicates that staining of both of the affected slides was performed using on-the-instrument factory default *dewax protocol, with factory default heat induced epitope retrieval (hier) protocol *hier 40 min and er1/ and custom staining protocol "her2 joes dab" with leica biosystems bond ready to use primary antibody *c-erbb-2 oncoprotein (clone cb11) catalog no: pa0571 and the bond polymer refine detection kit.The class i, bond ready-to-use primary antibody c-erbb-2 oncoprotein (cb11) instructions for use contain the following information: "the clinical interpretation of any staining or its absence should be complemented by morphological studies and proper controls and should be evaluated within the context of the patient's clinical history and other diagnostic tests by a qualified pathologist.", and "c-erbb-2 oncoprotein (cb11) primary antibody was developed for use on the automated bond system (includes leica bondmax system and leica bond-iii system) in combination with bond polymer refine detection.The recommended staining protocol for c-erbb-2 oncoprotein (cb11) primary antibody is ihc protocol f.Heat induced epitope retrieval is recommended using bond epitope retrieval solution 2 for 20 minutes." the facts indicate that the bond ready-to-use primary antibody c-erbb-2 oncoprotein (cb11) was not used in accordance with the manufacturer recommendations detailed in the instructions for use (ifu), because the available information indicates that the affected slides were stained using bond epitope retrieval solution 1 for 40 minutes rather than the recommended bond epitope retrieval solution 2 for 20 minutes; and the custom "her2 joes dab" protocol used for staining of the affected slides is not identical to the recommended ihc protocol f.Leica biosystems newcastle cannot assess the impact this may or may not have had on the quality of staining of the affected slides.The information available suggests that run 20651 and run 21164 had both positive and negative tissue controls run.However, information available does not indicate the type of control tissue used and whether they were placed on the same slides as the tissue for case id (b)(6) and case id (b)(6) in line with the instrument manufacturer recommendations in section 6.2 of the leica biosystems bond system user manual for bond systems running bond 6.0 software (for use only in the usa) entitled "working with controls".The run events for run 20651and run 21164 do not suggest that slides with control tissue were placed on the same ssa as bond slide id 299e with case id (b)(6) and bond slide id 2bq8 for case id (b)(6) manufacturer evaluation of the information available did not identify any instrument-or reagent related root cause for the reported false positive staining of bond slide id 299e with case id (b)(6) and bond slide id 2bq8 for case id (b)(6) following processing using bond-iii automated stainer serial number (b)(4).The root cause of the false positive staining reported by the complainant on (b)(6) 2021 could not be determined from the information available.
 
Event or Problem Description
On (b)(6) 2021 at 1:39pm eastern i received an email from (b)(6), lab supervisor stating that they had a patient that was misdiagnosed on (b)(6) 2021 according to a positive her-2 result.The patient received chemotherapy based on the positive result.On (b)(6) 2021 there was a 2nd patient with questionable results.The clinician asked for a repeat of the 2nd patient specimen which turned out to be negative.The negative result from the 2nd patient prompted the lab to re-test the 1st patient from (b)(6).The repeat specimen from (b)(6) was negative.The clinician was notified of the corrected result.The clinician informed the lab the patient had already started chemotherapy.Thus bringing us to current status.Refer to report mrf 3004859032 2022 0001 for details of patient involved.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BOND¿ READY-TO-USE PRIMARY ANTIBODY C-ERBB-2 ONCOPROTEIN
Common Device Name
BOND¿ READY-TO-USE PRIMARY ANTIBODY C-ERBB-2 ONCOPROTEIN - PA0571
Manufacturer (Section D)
LEICA BIOSYSTEMS NEWCASTLE LTD
balliol business park west
benton lane
newcastle upon tyne, north tyneside NE12 8EW
UK  NE12 8EW
Manufacturer (Section G)
LEICA BIOSYSTEMS
balliol business park west
benton lane
newcastle upon tyne, north tyneside NE12 8EW
UK   NE12 8EW
Manufacturer Contact
justine reed
balliol business park west
benton lane
newcastle upon tyne, north tyneside NE12 - 8EW
UK   NE12 8EW
MDR Report Key13385174
Report Number3004859032-2022-00002
Device Sequence Number11995828
Product Code NJT
UDI-Device Identifier05055331327901
UDI-Public05055331327901
Combination Product (Y/N)N
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 01/27/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date05/28/2021
Device Model NumberPA0571
Device Catalogue NumberPA0571
Device Lot Number70113
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/30/2021
Initial Report FDA Received Date01/28/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured06/03/2021
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient Age68 YR
Patient SexFemale
-
-