Model Number 381112
Medical Device Problem Code Connection Problem (2900)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/06/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
A device evaluation is anticipated but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event or Problem Description
It was reported that the bd angiocath¿ iv catheter hub would not connect to the extension tubing during use.The following information was provided by the initial reporter, translated from (b)(6): "this is a report about a connection issue of angiocath.The customer reported as follows: this occurred in an outpatient pediatric setting on (b)(6) 2022.After catheter placement, the hcp connected it to non-bd¿s extension tubing (surplug ad) but it was not locked, spinning only.The hcp pressed it strongly and fixed it with a tape, and then removed it on (b)(6) 2022.The hcp is stating that there might be a defect on the catheter hub.".
 
Additional Manufacturer Narrative
H.6.Investigation: bd received a 24 gauge angiocath device from lot 9157626 for evaluation.A review of the device history record was performed for the reported lot and no quality issues were found during production.Our quality engineer visually inspected the returned unit and observed that the thread's of the adapter were damaged.Based off the visual inspection the engineer was able to verify the reported defect.It was determined that there was a misalignment between the transfer arm and the chuck holder.The manufacturing facility has been notified of this incident and the findings.H3 other text : see h.10.
 
Event or Problem Description
It was reported that the bd angiocath¿ iv catheter hub would not connect to the extension tubing during use.The following information was provided by the initial reporter, translated from japanese: "this is a report about a connection issue of angiocath.The customer reported as follows: this occurred in an outpatient pediatric setting on 01/06/2022.After catheter placement, the hcp connected it to non-bd¿s extension tubing (surplug ad) but it was not locked, spinning only.The hcp pressed it strongly and fixed it with a tape, and then removed it on 01/11/2022.The hcp is stating that there might be a defect on the catheter hub.".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD ANGIOCATH¿ IV CATHETER
Common Device Name
INTRAVASCULAR CATHETER
Manufacturer (Section D)
BECTON DICKINSON INDUSTRIAS CIRURGICAS, LTDA.
ave. pres.juscelino kubitschek
273 francisco bernardino
juiz de fora
Manufacturer (Section G)
BECTON DICKINSON INDUSTRIAS CIRURGICAS, LTDA.
ave. pres.juscelino kubitschek
273 francisco bernardino
juiz de fora
Manufacturer Contact
phillip emmert
9450 south state street
sandy, UT 84070
8015296192
MDR Report Key13385798
Report Number9610048-2022-00003
Device Sequence Number16572957
Product Code FOZ
UDI-Device Identifier30382903811121
UDI-Public30382903811121
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K151698
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 03/31/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/31/2024
Device Model Number381112
Device Catalogue Number381112
Device Lot Number9157626
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/13/2022
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/11/2022
Supplement Date Received by Manufacturer03/31/2022
Initial Report FDA Received Date01/28/2022
Supplement Report FDA Received Date04/13/2022
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured06/26/2019
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-