SISTEMAS MEDICOS ALARIS, S.A. DE C.V. BD ALARIS PUMP MODULE SMARTSITE LOW SORBING INFUSION SET; INTRAVASCULAR ADMINISTRATION SET Back to Search Results
Model Number 24600-0007
Medical Device Problem Code Leak/Splash (1354)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/12/2021
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that the bd alaris pump module smartsite low sorbing infusion set experienced leakage.The following information was provided by the initial reporter: shortly after nurse (b)(6) chemo, patient called out and stated that something was leaking.Infusion stopped.Chemo infusion set noted to be leaking from extension piece.
 
Additional Manufacturer Narrative
Date of birth: only the patient's age was provided, therefore a default date of birth has been listed.Device expiration date: unknown.Fda notified: the initial reporter also notified the fda via medwatch uf/importer report #: (b)(4).A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.Device manufacture date: unknown.
 
Event or Problem Description
It was reported that the bd alaris pump module smartsite low sorbing infusion set experienced leakage.The following information was provided by the initial reporter: shortly after nurse hung chemo, patient called out and stated that something was leaking.Infusion stopped.Chemo infusion set noted to be leaking from extension piece.
 
Additional Manufacturer Narrative
H.6.Investigation: no product or photo was returned by the customer.The customer complaint of leakage from the extension piece could not be verified due to the product not being returned for failure investigation.The root cause of this failure could not be identified without a failure investigation.A device history record review could not be performed on model 24600-0007 because the lot number is unknown.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD ALARIS PUMP MODULE SMARTSITE LOW SORBING INFUSION SET
Common Device Name
INTRAVASCULAR ADMINISTRATION SET
Manufacturer (Section D)
SISTEMAS MEDICOS ALARIS, S.A. DE C.V.
blvd. insurgentes no. 20351
parque industrial el florido
tijuana
Manufacturer (Section G)
SISTEMAS MEDICOS ALARIS, S.A. DE C.V.
blvd. insurgentes no. 20351
parque industrial el florido
tijuana
Manufacturer Contact
phillip emmert
9450 south state street
sandy, UT 84070
8015296192
MDR Report Key13386102
Report Number9616066-2022-00036
Device Sequence Number1817387
Product Code FPA
UDI-Device Identifier50885403241978
UDI-Public50885403241978
Combination Product (Y/N)N
Initial Reporter StateMO
Initial Reporter CountryUS
PMA/510(K) Number
K944320
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 02/23/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number24600-0007
Device Catalogue Number24600-0007
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/07/2021
Supplement Date Received by Manufacturer02/23/2022
Initial Report FDA Received Date01/28/2022
Supplement Report FDA Received Date03/15/2022
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age39 YR
Patient SexFemale
-
-