MAUDE Adverse Event Report: LEICA BIOSYSTEMS NEWCASTLE LTD BOND¿ READY-TO-USE PRIMARY ANTIBODY C-ERBB-2 ONCOPROTEIN; BOND¿ READY-TO-USE PRIMARY ANTIBODY C-ERBB-2 ONCOPROTEIN - PA0571

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

LEICA BIOSYSTEMS NEWCASTLE LTD BOND¿ READY-TO-USE PRIMARY ANTIBODY C-ERBB-2 ONCOPROTEIN; BOND¿ READY-TO-USE PRIMARY ANTIBODY C-ERBB-2 ONCOPROTEIN - PA0571 Back to Search Results
Model Number PA0571
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 10/10/2021
Type of Reportable Event Serious Injury
Event or Problem Description
On (b)(6) 2021, leica biosystems (lbs) received an email from the laboratory supervisor detailing that the laboratory was experiencing staining issues the c-erb-2 clone cb11 antibody product number pa0571 and were concerned that there may be two misdiagnosed patients due to overstaining with this antibody, which had resulted in false positive results.Additional details provided by the laboratory supervisor stated, ".That they had a patient that was misdiagnosed on (b)(6) 2021 according to a positive her-2 result.The patient received chemotherapy based on the positive result.On (b)(6) 2021 there was a 2nd patient with questionable results.The clinician asked for a repeat of the 2nd patient specimen which turned out to be negative.The negative result from the 2nd patient prompted the lab to re-test the 1st patient from (b)(6).The repeat specimen from (b)(6) was negative.The clinician was notified of the corrected result.The clinician informed the lab the patient had already started chemotherapy." patient identifier information was provided for each of the two (2) affected patients.Refer to importer report number, (b)(4) for details of the other patient involved.The leica biosystems melbourne (manufacturer of the bond staining instrument) did not identify any instrument-related root cause for the reported false-positive staining on affected patients: (b)(6).Refer to lbs (b)(4) manufacturer report numbers: 8020030-2022-00009 and 8020030-2022-00010 for more information.The leica biosystems (b)(4) ltd.(manufacturer of the bond¿ ready-to-use primary antibody c-erbb-2 oncoprotein - pa0571) did not identify any reagent-related root cause for the reported false-positive staining on affected patients: (b)(6).Refer to lbs (b)(6) manufacturer report numbers: 3004859032-2022-00001 and 3004859032-2022-00002 for more information.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BOND¿ READY-TO-USE PRIMARY ANTIBODY C-ERBB-2 ONCOPROTEIN
Common Device Name
BOND¿ READY-TO-USE PRIMARY ANTIBODY C-ERBB-2 ONCOPROTEIN - PA0571
Manufacturer (Section D)
LEICA BIOSYSTEMS NEWCASTLE LTD
balliol business park west
benton lane
newcastle upon tyne, north tyneside NE12 8EW
UK  NE12 8EW
MDR Report Key13387982
Report Number1423337-2022-00003
Device Sequence Number19261280
Product Code NJT
UDI-Device Identifier05055331327901
UDI-Public05055331327901
Combination Product (Y/N)N
Initial Reporter StateMI
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Importer
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 01/28/2022
Report Date (Section F) 01/28/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date05/28/2021
Device Model NumberPA0571
Device Catalogue NumberPA0571
Device Lot Number70113
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? Yes
Distributor Facility Aware Date12/30/2021
Event Location Hospital
Date Report to Manufacturer01/28/2022
Initial Date Received by Manufacturer Not provided
Initial Report FDA Received Date01/28/2022
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient Age48 YR
Patient SexFemale
Date Report Sent to FDA01/28/2022
-
-