Reported by the dm via email on behalf of the customer - the stent sheath separated and the stent was not able to be deployed.The following has been requested- jm 10jan2022.The following has been answered- jm 12jan2022.Did any unintended section of the device remain inside the patient¿s body? no.If yes, please describe.Did the patient require any additional procedures due to this occurrence? no.Did the product cause or contribute to the need for additional procedures? no.If yes, please specify additional procedures and provide details.Has the complainant reported any adverse effects on the patient due to this occurrence? no.Has the complainant reported that the product caused or contributed to the adverse effects? no.Please specify adverse effects and provide details.Was the patient hospitalized or was there prolonged hospitalization due this occurrence? no.The following has been requested- jm 10jan2022.The following has been answered- jm 10jan2022.Please provide a customer contact person including their name, title and contact information: (b)(6).Will this be reported to the fda? no.Would the customer like an acknowledgment letter? yes.Please choose an appropriate account action for the customer: no charge replacement.No charge replacement, credit issued, no action.Is the device available for return? yes- i have it and will send today.Did the device make patient contact? yes.The following has been requested- jm 10jan2022.The following has been answered- jm 12jan2022.Are images of the device or procedure available? n/a, yes, no yes, it was a picture i sent in of the product.At what stage of the procedure did the complaint occur? unpacking or preparation, insertion, during stent placement, removing the introducer post stent placement.Insertion.Was a sphincterotomy performed prior to use of the stent device? n/a, yes, no.Yes.Was balloon dilation performed prior to use of the stent device? n/a, yes, no.No.What was the length and diameter of the stricture? (common bile duct-3-4cm length).What brand of endoscope was used with the device? olympus.Was the product inspected for kinks or damage before use? n/a, yes, no.Yes.What was the position of the elevator during deployment? n/a, open, closed.Open.Was the delivery system tracked around a tight angle in the patient anatomy or around a tight angle in an endoscope? n/a, yes, no.No, it was high and the elevator was down-would not release.Was the device flushed through both flushing ports before the procedure, as per ifu? n/a, yes, no.Yes with water.Details of the wire guide used (name, diameter, hydrophyllic)? olympus visiglide.What was the target location for the stent? through common bile duct into hylar region.Was the red safety lock removed before inserting the delivery system? n/a, yes, no.No, was the red safety lock removed before stent deployment? n/a, yes, no, yes, was the patient's anatomy tortuous? (fairly tight but not tortuous.Hylar strictures are pretty tight in general).Did the patient exhibit altered anatomy? n/a, yes, no.No.If yes, please specify the type of altered anatomy: did the patient have any pre-existing conditions? n/a, yes, no.Yes, stricture high in cbd.If yes, please state the specific condition(s): was resistance encountered when advancing the wire guide to the target location? n/a, yes, no.Not sure.If yes, how did the physician deal with this resistance? was resistance encountered when advancing the delivery system to the target location? n/a, yes, no.No.If yes, how did the physician deal with this resistance? was there resistance felt passing the delivery system through the stricture? n/a, yes, no.No.Was any damage noted on the wire guide before, during or after the procedure? n/a, yes, no.No.Did the tip of the delivery system cross the target location? yes.Was the handle pulled toward the hub during deployment? n/a, yes, no.Yes, but the outer sheath would not move and it separated.Was the delivery system pushed during deployment? n/a, yes, no.No.Was the stent being placed through the side wall of a previously placed stent? n/a, yes, no.No, it was not paced-bec.The outer sheath broke.Was the stent deployed smoothly / without resistance? n/a, yes, no.No, see # 25.Was the stent fully deployed before removing the delivery system from the patient? n/a, yes, no.No.Did any part of the product snag/get caught on the stent when removing the delivery system? n/a, yes, no.No, was never placed.Just the entire introducer with stent was removed.Was post-dilation performed after the placement of the stent? n/a, yes, no.No.Did the patient require any additional procedures as a result of this event? n/a, yes, no.No.If yes, what intervention was required? was the secondary intervention performed during the same procedure as the device failure or was it scheduled for another day? [n/a, same procedure, another day] same procedure, another day] placed 2 evolution biliary instead.Were any other defects (other than the complaint issue) observed on the delivery system prior to return? [n/a, yes, no].If yes, please specify what other defect(s) were observed.
|